Laserfiche WebLink
PRODUCT • 4 <br /> Product Specification <br /> f . Product Ref : ConCore® Panei 24 It with PosiLock TMUnderstructur& <br /> (b) Uniform Load : (g) Panel Cutout : <br /> Panel shall be capable of supporting a uniform load of Panel with up to a 101 /2" x 101 /2" cutout within <br /> the <br /> 3D0 Il.�s . plrlced on a one square foot area at any interior of the panel shall be capable of withstanding <br />an <br /> location on the panel with a maximum top surface ultimate load without failure of 1500 lbs , anywhere <br /> on <br /> deflection of 0 . 060 inches . Panel shall not exceed a the panel . <br /> peunanent sol of 0 . 010 inches , after the load is (h) Earthquake Load Performance: <br /> removed . Note: 71 re uniform load rating of an access Provide access flooring capable of withstanding a lateral <br /> floor panel <hs specified . herein should not be confused seismic force (Fp) in seismic zone applicable to this f <br /> will ) the 'uniform live load' as specified in seismic zone Project according to requirements outlined in 1997 <br /> applications. UBC . <br /> (c) Ultimate Load : (i) Flammability: <br /> ranel'shall be capable of withstanding a concentrated Access floor panels and supporting pedestals shall be <br /> load ofmlbs . applied onto a one square inch area non-combustible . Floor coverings selected for use on <br /> (using a round or square indentor) at any location on the access floor panels shall meet a Class A Flame Spread <br /> panel without failure . Failure is defined as the point at and smoke development requirement as tested per <br /> which the panel will no longer accept the load . Certified ASTM -E84 . <br /> . test report shall be provided attesting to this ultimate <br /> • 1 .5 Design Requirements: <br /> load . <br /> d) Rolling Load : <br /> (a) Quantities , finished floor heights (FFH) and location <br /> _, <br /> Parcel and supporting understructure shall be able to of accessories shall be as specified on the contract <br /> withstand the following rolling loads at any location on drawings . <br /> the panel without developing a local and overall surface (b) Access floor system , where indicated on the design <br /> deformation greater than 0 . 040 inches . Note: wheel l documents , shall consist of modular and removable <br /> and wheel 2 tests shall be performed on two separate cementitious filled welded steel panels fastened onto, <br /> panels. and supported by, adjustable height pedestal <br /> assemblies . <br /> Wheel 1: Size : 3 " dia x 110/i ';" wide <br /> Load .,)POO lbs Passes : 10 Pedestal head and panel corner design must provide a <br /> Wheel 2 : Size : 6" dia x 11/2" wide positive location and lateral engagement of the panel to <br /> LoadpO <br /> ppO lbs Passes : 10 , 000 <br /> the understructure support system without the use of <br /> • <br /> fasteners . Cavity created under the access floor shall 4 : 03 <br /> (e) Impact Load : be used for Underfloor HVAC , wire and cable <br /> Panel and supporling understructure shall be capable of management therefore close coordination with the <br /> supporting an impact load of 100 lbs . dropped from a Mechanical System (Division 15) and Electrical System <br /> height of 36 " onto a one square inch area (using a (Division 16) is required . <br /> round or square indentor) at any location on the panel (c) Panel shall be easily removed by one person with a <br /> wilflout failure . lifting device and shall be interchangeable except where <br /> (f) Panel Drop Test : cut for special conditions . <br /> Panel shall be capable of being dropped face up onto <br /> • to a concrete slat from a h6lgfit of 36" , after which it <br /> shall continue to meet all load performance <br /> requirements as previously defined . <br /> Tate <br /> ACCESS FLOORS <br /> /0220 - 3 <br />