Laserfiche WebLink
B. The piping systems require two (2) consecutive daily samples taken from the <br />locations called out on the plans or as determined by the Engineer. The <br />samples shall be taken at all the respective sample point locations. <br />C. Sampling must be coordinated with Engineer and other construction activities <br />so as to minimize re -sampling. <br />D. Contractor shall submit schedule for bacteriological testing and pressure tests. <br />E. The Contractor shall incur all costs needed to provide bacteriological <br />clearance of the piping systems. <br />3.11 QUALITY CONTROL <br />A. The laboratory and personnel collecting bacteriological samples shall be <br />Florida State certified in accordance with FDEP requirements. <br />+ + END OF SECTION + + <br />GENERAL PROVISIONS <br />01025-21 <br />F:\Engineering\Capital Projects\0216-12th Street Between 16th Avenue and 11th Place\0216 Bid Documents\DIVISION 2 - Technical <br />Provisions.doc <br />