Official Document Type
Contract
Approved Date
07/01/2008
Control Number
2008-213
Agenda Item Number
8.AA.
Entity Name
Ocean Gate General Contractors
Subject
Wabasso Beach Park Restoration
Area
Wabasso Beach
Bid Number
2008032
Supplemental fields
SmeadsoftID
7475
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 . Install clips to substrate with self-tapping fasteners . <br /> 2 . Install pressure plates at locations indicated in equipment manufacturer's written installation <br /> instructions . <br /> 3 . Before panels are joined, apply continuous bead of sealant to top of flange of lower panel. <br /> 4 . Snap-On Seam: Nest standing seams and fasten together by interlocking and completely engaging <br /> field-applied sealant. <br /> 5 . Seamed Joint: Crimp standing seams with manufacturer-approved motorized seamer tool so cleat, <br /> sheet metal roofing, and field-applied sealant are completely engaged. <br /> C. Seal joints as shown and as required for watertight construction. For roofing with 3 : 12 slopes or less, use <br /> cleats at transverse seams. <br /> 1 . Where sealant-filled joints are used, embed hooked flanges of joint members not less than 1 inch <br /> (25 mm) into sealant. Form joints to completely conceal sealant. When ambient temperature at <br /> time of installation is moderate, between 40 and 70 deg F (4 and 21 deg C), set joint members for <br /> 50 percent movement either way. Adjust setting proportionately for installation at higher ambient <br /> temperatures. Do not install sealant-type joints at temperatures below 40 deg F (4 deg Q . <br /> 2 . Prepare joints and apply sealants to comply with requirements in Division 7 Section " Joint <br /> Sealants. " <br /> 3 . 5 ACCESSORY INSTALLATION <br /> A. General: Install accessories with positive anchorage to building and weathertight mounting and provide <br /> for thermal expansion. Coordinate installation with flashings and other components. <br /> 1 . Install components required for a complete sheet metal roofing assembly including trim, copings, <br /> seam covers, flashings, sealants, gaskets, fillers, metal closures, closure strips, and similar items . <br /> 2 . Install accessories integral to sheet metal roofing that are specified in Division 7 Section " Sheet <br /> Metal Flashing and Trim" to comply with that Section's requirements. <br /> B . Flashing and Trim: Comply with performance requirements, manufacturer's written installation <br /> instructions, and SMACNA's "Architectural Sheet Metal Manual . " Provide concealed fasteners where <br /> possible, and set units true to line and level as indicated. Install work with laps, joints, and seams that <br /> will be permanently watertight and weather resistant. <br /> 1 . Install flashing and trim as required to seal against weather and to provide finished appearance . <br /> Locations include, but are not limited to, eaves, rakes, corners, bases, framed openings, ridges, <br /> fasciae, and fillers . <br /> 2 . Install continuous strip of self-adhering underlayment at edge of continuous flashing overlapping <br /> self-adhering underlayment, where " continuous seal strip " is indicated in SMACNA's <br /> "Architectural Sheet Metal Manual, " and where indicated on Drawings . <br /> 3 . Install exposed flashing and trim without excessive oil canning, buckling, and tool marks and true <br /> to line and levels indicated, with exposed edges folded back to form hems . Install sheet metal <br /> flashing and trim to fit substrates and to result in waterproof and weather-resistant performance . <br /> 4 . Expansion Provisions : Provide for thermal expansion of exposed flashing and trim. Space <br /> movement joints at a maximum of 10 feet (3 m) with no joints allowed within 24 inches (600 mm) <br /> of comer or intersection. Where lapped expansion provisions cannot be used or would not be <br /> sufficiently weather resistant and waterproof, form expansion joints of intermeshing hooked <br /> flanges, not less than 1 inch (25 nun) deep, and filled with butyl sealant concealed within joints . <br /> Wabasso Beach Park 07610 - 9 <br /> Indian River County <br /> DAA Project No . 6008 <br />