Laserfiche WebLink
C , Twist: Plus or minus 1 / 16 inch ( 1 . 6 mm), measured at opposite face corners of jambs on <br /> parallel lines, and perpendicular to plane of wall. <br /> d. Plumbness : Plus or minus 1 / 16 inch ( 1 . 6 mm), measured at jambs at floor. <br /> C. Stainless-Steel Doors : Fit non-fire-rated doors accurately in frames with the following clearances : <br /> 1 . Non-Fire-Rated Doors : <br /> a. . Jambs and Head: 1 /8 inch (3 mm) plus or minus 1 / 16 inch ( 1 . 6 mm) . <br /> b . Between Edges of Pairs of Doors : 1 /8 inch (3 mm) plus or minus 1 / 16 inch ( 1 . 6 mm) . <br /> C , Between Bottom of Door and Top of Threshold: Maximum 3/8 inch (9 . 5 mm) . <br /> d. Between Bottom of Door and Top of Finish Floor (No Threshold) : Maximum 3/4 inch ( 19 <br /> mm) . <br /> 3 .4 ADJUSTING AND CLEANING <br /> A. Final Adjustments: Check and readjust operating hardware items immediately before final inspection. <br /> Leave work in complete and proper operating condition. Remove and replace defective work including <br /> stainless-steel doors or frames that are warped, bowed, or otherwise unacceptable. <br /> B . Clean grout and other bonding material off stainless-steel doors and frames immediately after installation. <br /> C . Stainless-Steel Touchup : Immediately after erection, smooth any abraded areas of stainless steel and <br /> polish to match undamaged finish. <br /> END OF SECTION 08130 <br /> Wabasso Beach Park 08130 - 7 <br /> Indian River County <br /> DAA Project No. 6008 <br />