My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-227B.1
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-227B.1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2016 2:01:00 PM
Creation date
10/1/2015 5:04:28 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Addendum
Approved Date
12/18/2012
Control Number
2012-227B.1
Agenda Item Number
8.V.
Entity Name
Barth Construction, Inc.
Subject
Addendum No. 1, 2, 3
South County Regional Park
Area
Multi-Purpose Field
Bid Number
2013009
Supplemental fields
SmeadsoftID
11697
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
installed near the shelter between Fields 3 and 4 . Additionally, one ( 1 ) water fountain <br />is to be <br /> installed east of Field 1 near the bleachers and one ( 1 ) water fountain is to be installed west of Field 4 <br /> near the bleachers . <br /> QUESTION NO. 9 <br /> Is the Project Site earthwork expected to Balance? Or is import fill expected ? <br /> ANSWER NO. 9 <br /> It is expected that borrow material (AASHTO Classification A-3 fill material with maximum 10% passing <br /> the 200 sieve ) will be required . It is the contractor' s responsibility to determine the amount of import <br /> fill material that is needed for the project . <br /> QUESTION NO. 10 <br /> Since the Geotech report of the subsurface and physical conditions was not included with the contract <br /> documents, Are there any unsuitable materials or any other subsurface conditions expected that <br /> could adversely affect the construction and installation of any of the bid items? ( Excluding <br /> groundwater) <br /> ANSWER NO. 10 <br /> There is no known unsuitable material or adverse subsurface conditions at the site . <br /> QUESTION NO. 11 <br /> Please provide the width of the underdrain trenches, the detail on sheet C-6 does not seem correct. It <br /> shows 2 under drain pipes approx 3 feet apart . Sheet C- 5 does not indicate 32 under drain pipes that <br /> close to each other. <br /> ANSWER NO. 11 <br /> The detail is correct . Each underdrain trench location shall have 2 — 4" perforated pipes and a total of <br /> 9' width of rock and well draining soils . ( FDOT Standard Specification Filter Material for Underdrains <br /> shall be followed . ) Bid Item No . 12 has been modified to clarify the work involved . <br /> QUESTION NO. 12 <br /> Please provide the locations of the proposed (8 ) electric water coolers . <br /> ANSWER NO. 12 <br /> Please see No . 8 above . <br /> Page 4 of 11 <br /> F:\Public Works\ENGINEERING DIVISION PROJECTS\ 1126 - South Co Park Multi Purpose Fields\Admim\bid documents\Addendum No. 3 11 - 1342.doc <br /> F <br />
The URL can be used to link to this page
Your browser does not support the video tag.