My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-227B.1
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-227B.1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2016 2:01:00 PM
Creation date
10/1/2015 5:04:28 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Addendum
Approved Date
12/18/2012
Control Number
2012-227B.1
Agenda Item Number
8.V.
Entity Name
Barth Construction, Inc.
Subject
Addendum No. 1, 2, 3
South County Regional Park
Area
Multi-Purpose Field
Bid Number
2013009
Supplemental fields
SmeadsoftID
11697
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. One meter, served by FPL transformer, will serve lift station, independent restroom, well and <br /> irrigation system , and small shelters . ( Note the lift station will be serviced by this meter and <br /> NOT one at the lift station itself. Same 120/240V as identified in B above . <br /> GENERAL NOTES : All conduit transformers will be installed and provided by FPL under separate <br /> contract with Indian River County. All transformers are intended to be east of the concession <br /> building. Meters are to be located in one area on concession building. <br /> Item C above affects the following: 1 . B . 7 . b . 25 <br /> A. Section 45 — Remove "However, the Sanitary Lift Station electrical utilities will be served from a <br /> separate transformer meter will be at the Lift Station ." <br /> B . Response to Pre- Bid Question No . 3 . The Lift Station will NOT have a separate meter. <br /> C . Addendum No . 2 response to Section 45 — 1 . B. 7 . b . 25 Same as above . <br /> See revised Section 45 — Concession/Restroom Building, Page 27 - 29 <br /> QUESTION NO. 16 <br /> Please advise as to location of similar existing well and pump station as specified on note on plans L4 . <br /> ANSWER NO. 16 <br /> There are two ( 2 ) existing wells and pump stations near the multi- purpose baseball fields at the north <br /> end of the South County Regional Park. There are Parks Division personnel on-site from 7 : 30 a . m . — <br /> 3 : 00 p . m : every working day that can assist bidder in viewing systems . <br /> QUESTION NO . 17 <br /> Has the County applied to . the South Florida Water Management District or have the required <br /> consumptive water use permit for a "six inch " well which will be needed to supply the demand of ( 120 <br /> G . P . M . @ 60 P . S . I . ) as specified ? <br /> ANSWER NO. 17 <br /> No . It will be the Contractor' s responsibility to obtain required permits . <br /> QUESTION NO. 18 <br /> Please provide the width of the underdrain trenches, the detail on sheet C-6 does not seem correct . It <br /> shows 2 under drain pipes approx 3 feet apart . Sheet C-5 does not indicate 32 underdrain pipes that <br /> close to each other. <br /> ANSWER NO . 18 <br /> Please see No . 11 above . <br /> Page 6 of 11 <br /> FAPublic Works\ENGINEERING DIVISION PROJECTS\ I 126 - South Co Park Multi Purpose Fields\Admim\bid documents\Addendum No. 3 1143 - 12.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.