Laserfiche WebLink
QUESTION NO. 5 <br /> Is the County to exclude the FDOT 550 standard from the spec? Or will they sign off on a design that <br /> will not meet the standards called out in the specs . <br /> ANSWER NO. 5 <br /> No and no . <br /> QUESTION NO. 6 <br /> Section 550-3 . 6 will not be met with material, fencing system, applicable design standards, <br /> construction practices, or specifications . A much larger post will be required . Please advise . <br /> ANSWER NO . 6 <br /> Replacement of fabric material is considered maintenance work and not new construction . <br /> QUESTION NO. 7 <br /> Both 2" x 9 gauge steel core x 6 gauge finish and 2" x 9 gauge core x 8ga 2b finish are called out . Is <br /> either chain link mesh acceptable ? <br /> ANSWER NO. 7 <br /> The fencing must be 9 gauge metal core and 6 gauge finished (with the addition of the vinyl coating) . <br /> CLARIFICATIONS : <br /> Section 5 — Clearing and Grubbing <br /> A. Add the following to the end of the paragraph : <br /> "The limits of clearing and grubbing shall extend 4' outside the proposed fence around the <br /> multi- purpose fields, along with 2' outside the proposed walking trail on each side, necessary <br /> area around proposed parking areas, and area of concession/restroom building area , and <br /> maintenance/storage building area . " <br /> Section 16 — Fencing <br /> A. Section 16 has been changed to Section 20 to match Itemized Bid Schedule . <br /> A. 4 ) Remove the following : " Remove all 45 degree overhang framework. Extend posts 6' high to <br /> 20' total height . " <br /> A. 5 ) Bottom rail must be added to front edging fence at dugouts and to the 10' high fence where <br /> bottom rail is missing. Cost to be included in price of fencing. ' <br /> Page 3 of 6 <br /> F A1'ublic Work.AENGINEERING DIVISION PROJECTS\ 1126 - South Co Park Multi Purpose FieldsiAdmim\bid documents\Addendum No. 2 11 -81. 2.doc <br />