Laserfiche WebLink
❑ ( d ) When statistical procedures are used to calculate survey accuracies, the <br /> maximum acceptable positional tolerance, based on the 95% confidence level , should <br /> meet the same equivalent relative distance standards as set forth in 61G17- <br /> 6.003(3)( p)(2 .)(c) F.A.C . <br /> ❑ (e) Intended Display Scale : All maps or reports of surveys produced and delivered <br /> with digital coordinate files must contain a statement to the effect of: "This map is <br /> intended to be displayed at a scale of 11 or smaller". <br /> 61 G17-6.004 Specific Survey, Map, and Report Requirements <br /> ( 1 ) As-Buiit/Record Survey : <br /> ❑ (a) Obtained field measurements of vertical or horizontal dimensions of constructed <br /> improvements so that the constructed facility can be delineated in such a way that <br /> the location of the construction may be compared with the construction plans . <br /> ❑ ( b) Clearly shows by symbols, notations, or delineations, those constructed <br /> improvements located by the survey. <br /> ❑ (c) All maps prepared shall meet applicable minimum technical standards. <br /> ❑ (d) Vertical and horizontal accuracy of the measurements made shall be such that it <br /> may be determined whether the improvements were constructed consistent with <br /> planned locations. <br /> + + END OF SECTION + + <br /> 01025-19 Technical Specifications <br /> F:\Public Works\ENGINEERING DIVISION PROJECTS\0545-66Th Ave SR60 to 57th St (Arcadis)\Admim\Bid Documents\Technical <br />