ANSWER NO. 6 <br /> Indian River County Utilities Department stated that the 4" FM is currently not in use . Therefore, it <br /> can be isolated without any issues . <br /> QUESTION NO. 7 <br /> What is the cost for water for testing and flushing of the mains ? <br /> ANSWER NO. 7 <br /> The Contractor' s will not be charged a fee for the use of water to test and flush Indian River County <br /> Utilities Department facilities . <br /> QUESTION NO. 8 <br /> Are the mains that are to be deflected under the drainage to be DIP or PVC ? There is conflicting notes <br /> on the plans . <br /> ANSWER NO. 8 <br /> As shown in the detail on sheet UT -04, DIP with mechanical joints or concrete encasement is required <br /> if the vertical clearance between the two pipes is less than 18- inches . Separate payment will not be <br /> made for the use of Dip pipe or concrete encasement . <br /> QUESTION NO. 91 <br /> How will the deflected mains to be tested and cleared/Can the mains be visually inspected, <br /> chlorinated and flushed at each location ? Or do . we have to flush and re-clear the entire main ? Please <br /> clarify the main clearance procedures for the deflected existing water mains . <br /> ANSWER NO. 9 <br /> The reclaimed water main deflections will be visually inspected under pressure prior to backfilling. <br /> The potable water main shall have gate valves at both ends of each deflection and sample points for <br /> chlorinating and pressure testing in accordance with IRCUD standards . The cost for all testing shall be <br /> included in the price bid for pipe . Locations of line stops will be determined by IRCUD inspector prior <br /> to installation . <br /> QUESTION NO. 10 <br /> We' re having trouble locating the double barrel flumes (found one on sheet 105 ) . Please advise. . <br /> ANSWER NO. 10 <br /> The closed flume inlets are located on 33rd Street at station 410+25 and 421+30 and on 49TH Street at <br /> station 698+50 . <br /> QUESTION NO. 11 <br /> Per the bid specs on line 6460 item 5804-2- 1( Saw Palmetto ( FG, 18 ' HT x 10' SPR 4 " C, CH, SP AS ) e <br /> don 't know if this is a typo, but this is an unrealistic Spec . the largest they get is 4-5 ' max , is it possible <br /> to get clarification on this . <br /> ANSWER NO . 11 <br /> The saw palmetto should be 7G, 18" OA, F, @24" OC . In addition , in the Landscape Tabulation of <br /> Quantities for the Winkel residence buffer the symbol for the Live Oak trees should be QV-3 . . <br /> Page 3 of 14 <br /> F:'•,Public Works\ENGINEERING DIVISION PROJECTS10545-66Th Ave SR60 to 57th St (Arcadis)1Admim\Bid Documents\Addendum #2\Addendum No. 2 <br /> 11 -19-12.doc <br /> r <br />