2011-019
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2017 3:06:08 PM
Creation date
10/1/2015 1:38:07 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
02/01/2011
Control Number
2011-019
Agenda Item Number
8.G.
Entity Name
Florida Department of Environmental Protection
Subject
Algal Turf Scrubber System
Phase 1 Construction PC South
State Financial Assistance Agreement
Supplemental fields
SmeadsoftID
9249
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT H <br />Quality Assurance Requirements <br />1. All sampling and analyses performed under this Contract must conform to the requirements <br />set forth in Chapter 62-160, Florida Administrative Code (F.A.C.) and "Requirements for <br />Field and Analytical Work performed for the Department of Environmental Protection under <br />Contract' (DEP-QA-002/02), February 2002. <br />2. LABORATORIES <br />a. The CONTRACTOR shall ensure that all laboratory testing activities are performed by <br />laboratories certified by the Florida Department of Health Environmental Laboratory <br />Certification Program (DoH ELCP) for all applicable matrix/method/analyte combinations <br />to be measured. <br />b. If the laboratory is not certified for some or all of the proposed test measurements, the <br />laboratory shall apply for certification within one month of Contract execution. Within six <br />months of Contract execution the laboratory shall be fully certified for all applicable <br />matrix/method/analyte combinations to be performed. Regardless of when the <br />laboratory receives certification, the laboratory must implement all applicable standards <br />of the National Environmental Laboratory Accreditation Conference (NELAC) upon <br />Contract execution. <br />c. Laboratories shall maintain certification as specified in item 2.a above during the life of <br />the Contract. Should certification for an analyte or test method be lost, all affected tests <br />shall be immediately sub -contracted to a laboratory with current DoH ELCP certification <br />in the appropriate matrix/method/analyte combination(s). The CONTRACTOR shall <br />notify the DEP contract manager in writing before any change to a sub -contracted <br />laboratory is made <br />d. A copy of the DoH ELCP Certificate and the associated list of specific fields of <br />accreditation for each contracted or sub -contracted laboratory shall be provided to the <br />DEP contract manager upon Contract execution or upon receiving DoH certification (see <br />items 2.a and 2.b above) <br />e. The CONTRACTOR shall ensure that an acceptable initial demonstration of capability <br />(IDOC), as described in Appendix C of Chapter 5 of the NELAC Standards is performed. <br />Each laboratory that performs any of the proposed matrix/method/analyte combination(s) <br />must have the requisite IDOL documentation and supporting laboratory records. IDOCs <br />shall be performed before the test procedure is used to generate data for this Contract. <br />If requested by the Department, documentation that supports the IDOC shall be made <br />available for review <br />f. When performance test samples are not required by DoH ELCP for certification, the <br />laboratory shall obtain, analyze and evaluate performance test samples standard <br />reference materials (SRM) or other externally assayed quality control (QC) samples, <br />hereinafter known collectively as quality control check (QCC) samples. <br />(i) The laboratory shall ensure that the selected QCC samples(s) represent all <br />matrix/method/analyte combinations that are not subject to certification requirements. <br />(ii) These samples shall be analyzed at six-month intervals and the results shall be <br />within the acceptable range established by the QCC sample provider <br />(iii) Before providing analytical services for this Contract, the laboratory must provide to <br />the DEP contract manager the results of the QCC sample(s) and the associated <br />acceptable range(s) as established by the QCC sample provider. The submitted <br />results must be from QCC samples that have been completed within the previous six <br />months prior to the submission date <br />g. Any non-standard laboratory procedures or methods that are proposed for use (i.e., <br />those not approved by DEP for standard environmental analyses) shall be submitted for <br />review and approval in accordance with DEP-QA-001/01, "New and Alternative <br />DEP Agreement No. LP###, Attachment 11, Page 1 of 15 <br />