Laserfiche WebLink
Ir <br /> 71 <br /> AI I <br /> kl <br /> dp <br /> s ? <br /> 5444 Compensation. <br /> Price and payment will be full compensation for the complete system or module in place <br /> and accepted, including object marker or sheeting, and restoration of damaged attenuators . <br /> Relocation of an existing attenuator system to a permanent location called for in the plans <br /> shall be paid for at the Contract unit price for relocating existing systems . Price and payment will <br /> be full compensation for relocating and reinstalling the system in accordance with the <br /> manufacturer ' s instructions and the Design Standards . <br /> Payment will be made under: <br /> Item No . 544- 74- Relocate Crash Cushion, - each . <br /> Item No . 544- 75 - Crash Cushion - each . <br /> 546 RUMBLE STRIPS . <br /> (REV 7-6-09) (FA 8-3149) (140) <br /> ARTICLE 546 -2 (Page 679) is deleted and the following substituted : <br /> 546-2 Materials for Raised Rumble Strips. <br /> Construct Raised Rumble Strips using one of the following : <br /> (a) Thermoplastic materials listed on the Qualified Products List (QPL) , meeting <br /> the requirements of 971 - 1 and 971 -6 . Ensure that the material used can be restored to its original <br /> dimensions by using a self bonding overlay meeting these requirements . Submit a certified test <br /> r` report to the Engineer indicating that the materials meet all requirements specified. <br /> Before applying thermoplastic materials on portland cement concrete <br /> surfaces , apply a primer sealer recommended by the manufacturer. <br /> (b) Any plant-mixed hot bituminous mixture meeting the requirements of a job - <br /> mix formula issued by the Department, except open-graded friction course . <br /> Prior to the application of any plant-mixed hot bituminous material, apply <br /> a tack coat meeting the requirements of 300-2 . 3 . <br /> The mixture will be accepted on the basis of visual inspection by the <br /> Engineer with no further testing required . <br /> 548 RETAINING WALL SYSTEMS <br /> (REV 54740) (FA 6440) (1 - 11 ) <br /> ARTICLE 548 -2 (Pages 681 — 683 ) is deleted and the following substituted : <br /> 548-2 Materials . <br /> Purchase the precast components , soil reinforcement, attachment devices , joint filler, <br /> filter fabric , and all necessary incidentals from the wall supplier chosen . <br /> 548-2 . 1 Concrete : Ensure that concrete utilized for wall components is as specified in <br /> the Contract Documents and is consistent with the concrete class , environmental classification <br /> and admixture requirements for durability as stated in the Contract Documents . Produce and <br /> supply concrete for all wall components meeting the requirements of Section 346 . <br /> - 156 - <br /> FPID ( S ) : 423186 - 1 - 58 - 01 <br />