My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-226B.1
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-226B.1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2016 2:18:33 PM
Creation date
10/1/2015 3:12:48 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/01/2011
Control Number
2011-226B.1
Agenda Item Number
8.N.
Entity Name
Goodson Paving
Subject
Contract and Specifications Old Dixie Sidewalk
Volume II
Area
Old Dixie Highway from 38th Lane to 65th St.
Project Number
0845
Bid Number
2011045
Supplemental fields
SmeadsoftID
10419
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
optimum moisture and neither dry or saturated, and tamp to the extent directed by the Engineer. <br /> The Department may require that the backfilling be done with poured concrete . <br /> Install spread footings which support sign structures overhanging the roadway as <br /> required in 455 -25 through 455 - 37 . <br /> 7004 . 1 .2 Mixing and Placing Concrete : For batching and mixing of concrete <br /> for footings , meet the requirements of Section 346 , except that the Engineer will allow hand <br /> mixing by approved methods where the quantity to be mixed does not exceed 1 /2 yd3 . Use cast- <br /> in-place or precast concrete for the footings . Obtain precast concrete footings from a plant that is <br /> currently on the list of Producers with Accepted Quality Control Programs . Producers seeking <br /> inclusion on the list shall meet the requirements of 105 - 3 . <br /> 700-7. 1 .3 Forms : The Engineer will not require forms when the ground is <br /> sufficiently firm, in which case, sufficiently moisten the adjacent earth to prevent it from <br /> absorbing the moisture from the concrete . Where forms are required and the soil is not moist, <br /> place sufficient water, as directed by the Engineer, in the hole , and pour the concrete as soon as <br /> the water has been absorbed. Place at least 4 inches of loose earth, free from clods or gravel, over <br /> the top of the footing to effect curing. <br /> 7004. 1 .4 Finishing Concrete : Trowel the top of the concrete to a smooth finish . <br /> 7004 . 2 Drilled Shafts : Meet the requirements of Section 455 . <br /> 700-8 Erection of Signs and Sign Supports . <br /> Do not erect overhead sign supports until the concrete strength in the support footing is at <br /> least 2 , 500 psi . Determine concrete strength from tests on a minimum of two test cylinders <br /> sampled and tested in accordance with ASTM C 31 and ASTM C 39 and verifying test results <br /> have been provided to the Engineer. <br /> Erect the signs and sip structures in accordance with the details shown in the plans . The <br /> Contractor may fabricate the structural steel sign trusses in sections that will fit into available <br /> galvanizing vats . Prior to galvanizing, weld the joints as specified in 460 -6 and in accordance <br /> with the details shown in the plans . Re- galvanize damaged parts as specified in Section 562 . <br /> Weld aluminum structures in accordance with 965 -3 . <br /> Attach electronic display signs to the supporting structure in accordance with the <br /> manufacturer ' s recommendations using the mounting hardware provided by the manufacturer. <br /> 700.9 Removal or Relocation of Signs . <br /> Relocation of signs shall consist of removing the existing sign assembly and installing the <br /> sign on a new foundation . <br /> When the plans call for existing ground-mounted signs to be relocated or removed, <br /> immediately remove supports and footings that project more than 6 inches above the ground <br /> surface after removing the sign panel from the assembly. Remove existing footings to a depth at <br /> least 12 inches below the ground surface . The costs will be included in the Contract unit price of <br /> the item to which it is incidental . <br /> Notify the Engineer a minimum of 30 days prior to removal of existing Logo sign <br /> structures . <br /> 70040 Overlay Existing Sign Panels . <br /> Use 0 . 040 inch thick aluminum sheeting for overlays larger than 3 square feet placed on a <br /> sign panel . Replace hex head bolts on the sign surface using stainless steel flat head machine <br /> screws with nuts and lock washers to give a flat surface for the overlay panel . Install the overlay <br /> - 189 - <br /> FPID ( S ) : 423186 - 1 - 58 -01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.