2011-051
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-051
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/22/2016 1:43:27 PM
Creation date
10/1/2015 1:46:27 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
03/01/2011
Control Number
2011-051
Agenda Item Number
12.J.1
Entity Name
Beemats LLC
Subject
Floating Mat System
Area
Spoonbill Marsh Wetland Facility
Project Number
2785
Bid Number
2011029
Supplemental fields
SmeadsoftID
9309
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B . The operation , testing and adjustment shall be as required to prove that the equipment has <br /> been left in proper condition for satisfactory operation under the conditions specified . <br /> C . Upon completion of this work , the manufacturer' s field service technician shall submit a <br /> signed report of the results of his/her inspection , operation , adjustments and tests . <br /> 3 . 02 STARTUP AND ACCEPTANCE <br /> A . General Requirements <br /> I . Successfully execute the step - by- step procedure of startup and performance <br /> demonstration specified herein . <br /> 2 . The startup and performance demonstration shall be successfully executed prior <br /> to Substantial Completion and acceptance by the Owner. <br /> 3 . All performance tests and inspections shall be scheduled at least 5 working days <br /> in advance or as otherwise specified with the Owner and the Engineer. All <br /> performance tests and inspections shall be conducted during the workweek of <br /> Monday through Friday, unless otherwise specified . <br /> B . Preparation for Startup <br /> 1 . All mechanical and electrical equipment shall be checked to ensure that they are <br /> in good working order and properly connected . Preliminary equipment operation <br /> shall be conducted . All systems shall be cleaned and purged as required . All <br /> sumps, tanks, basins, chambers, pump wells and pipelines which are <br /> hydraulically checked shall be drained and returned to their original condition <br /> once the testing is complete. <br /> 2 . All instruments and controls shall be calibrated through their full range . All <br /> other adjustments required for proper operation of all instrumentation and control <br /> equipment shall be made . <br /> 3 . Perform all other tasks needed for preparing and conditioning the facilities for <br /> proper operation . <br /> 4 . No testing or equipment operation shall take place until it has been verified by <br /> the Resident Project Representative that all specified safety equipment has been <br /> installed and is in good working order. <br /> 5 . No testing or equipment operation shall take place until it has been verified by <br /> the Resident Project Representative that all lubricants, tools, maintenance <br /> equipment, spare parts and approved equipment operation and maintenance <br /> manuals have been furnished as specified . <br /> C . Facilities Startup <br /> 1 . Startup period shall not begin until all new facilities and equipment have been <br /> tested as specified and are ready for operation . The Owner shall receive spare <br /> parts , safety equipment, tools and maintenance equipment, lubricants , approved <br /> operation and maintenance data and the specified operation and maintenance <br /> instruction prior to the startup . All valve tagging shall also be complete prior to <br /> this startup . <br /> 2 . Demonstrate a seven consecutive day period of 24 hour per day Successful <br /> operation of the facility as a prerequisite of Substantial Completion and <br /> Acceptance . <br /> 3 . In the event of failure to demonstrate satisfactory performance of the facility on <br /> the first or any subsequent attempt, all necessary alterations, adjustments , repairs <br /> 01650- 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.