Laserfiche WebLink
must be flexible to allow a range of privileges such as full scheduling capabilities for all fields , to only <br /> having permission to execute " early off' commands by phone . <br /> Controller shall accept and store 7 -day schedules , be protected against memory loss during power <br /> outages , and shall reboot once power is regained and execute any commands that would have <br /> occurred during outage . <br /> a . Hours of Usage : Manufacturer shall provide a means of tracking actual hours of usage for the <br /> field lighting system that is readily accessible to the owner. <br /> i . Cumulative hours : shall be tracked to show the total hours used by the facility <br /> ii . Current lamp hours : shall be tracked separately to reflect the amount of hours on <br /> the current set of lamps being used , so relamping can be scheduled accurately <br /> F . Management Tools : Manufacturer shall provide a web -based database of actual field usage and <br /> provide reports by facility and user group . <br /> G . Communication Costs : Manufacturer shall include communication costs for operating the controls and <br /> monitoring system for a period of 25 years . <br /> 1 . 5 PLAYABILITY <br /> A . Weight Reduction on Cross Arm <br /> To prevent cross arms from sagging resulting in potential fixture misalignment , the ballasts <br /> shall be mounted in an electrical component enclosure on the pole separate from the fixture <br /> mounting <br /> B . Mounting Heights <br /> The pole mounting heights shall be minimum 90 ' <br /> 1 .6 MAINTENANCE EASE <br /> A. Electrical Component Enclosure Location <br /> To provide easy access to major electrical components , the electrical component enclosure <br /> shall be located approximately 10 feet above grade at the pole foundation . <br /> B . Aiming Recapture Device <br /> To assure quality of lighting on the field is maintained , light fixtures shall have a positive <br /> repositioning device for each luminaire on the assembly . The device shall provide for <br /> automatic repositioning of the aiming after relamping . In addition , there shall be a stainless <br /> steel bolt and nut to secure the alignment. <br /> C . Labeled Assembly <br /> For easy identification and reduced maintenance time , each ballast, capacitor, and fuse shall <br /> be labeled to identify the fixture it services . <br /> D . Electrical Component Enclosure Fusing <br /> To prevent multiple failures , an individual fuse shall be provided for each ballast conductor <br /> except neutral conductors . <br /> E . Spare Fuses <br /> For ease of maintenance , spare fuses and fuse puller will be located in the lowest numbered <br /> electrical components enclosure . <br /> 1 . 7 INSTALLATION EASE : <br /> A . Factory Wired <br /> To reduce on -site installation time and costs , all wiring of the lamp sockets , ballasts , <br /> capacitors , and fusing shall be done in the factory prior to shipment to the job site . <br /> 39 <br /> P :\Public Works\ENGINEERING DIVISION PROJECCS\ 1042 VB Sports Village Lighting\Admim\bid documents\Bid Docs VBSV Lighting revised <br /> 12- 13 - IO . doc <br />