ORDINANCE NO. 2005-048 <br />Exceptions: <br />1. Processing, storage and operation areas that require cooling or special <br />temperature conditions. <br />2. Areas in which persons are primarily engaged in vigorous physical activities. <br />(5) Room temperature measurement. The required room temperatures shall be <br />measured 3 feet (914mm) above the floor near the center of the room and 2 feet (610 <br />mm) inward from the center of each exterior wall. <br />Section 403.25 Mechanical Equipment. <br />(1) Mechanical appliances. All mechanical appliances, fireplaces, solid fuel - <br />burning appliances, cooking appliances and water heating appliances shall be properly <br />installed and maintained in a safe working condition, and shall be capable of performing <br />the intended function. <br />(2) Removal of combustion products. All fuel -burning equipment and appliances <br />shall be connected to an approved chimney or vent. <br />Exception: Fuel -burning equipment and appliances which are labeled for <br />unvented operation. <br />(3) Clearances. All required clearances to combustible materials shall be <br />maintained. <br />(4) Safety controls. All safety controls for fuel -burning equipment shall be <br />maintained in effective operation. <br />(5) Combustion air. A supply of air for complete combustion of the fuel and for <br />ventilation of the space containing the fuel -burning equipment shall be provided for the <br />fuel -burning equipment. <br />(6) Energy conservation devices. Devices intended to reduce fuel consumption by <br />attachment to a fuel -burning appliance, to the fuel supply line thereto, or to the vent <br />outlet or vent piping there from, shall not be installed unless labeled for such purpose <br />and the installation is specifically approved. <br />Section 403.26 Electrical Facilities. <br />(1) Facilities required. Every occupied building shall be provided with an electrical <br />system in compliance with the requirements of this section and Section 403.26(2). <br />(2) Service. The size and usage of appliances and equipment shall serve as a basis <br />for determining the need for additional facilities in accordance with the NEC 2002. <br />Dwelling units shall be served by a three -wire, 120/240 volt, single phase electrical <br />service having a rating of not less than 60 amperes. <br />Coding: Words underscored are additions to text; words in strikethrough format are <br />deletions to text. <br />21 <br />