Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />4. Door Bumper: Manufacturer's standard heavy-duty rubber -tipped bumper at out -swinging <br />doors and entrance -screen doors. Mount with through -bolts. <br />5. Door Pull: Manufacturer's standard heavy-duty pull at out -swinging doors that complies <br />with regulatory requirements for accessibility. Provide units on both sides of doors at <br />compartments designated as accessible. Mount with through -bolts. <br />B. Overhead Bracing: If required manufacturer's standard continuous, extruded -aluminum head rail <br />with antigrip profile and in manufacturer's standard finish. <br />C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel, finished <br />to match the items they are securing, with theft -resistant -type heads. Provide security torx head <br />bolts for through -bolt applications. For concealed anchors, use plastic anchors. <br />D. Aluminum Extrusions: ASTM 64663-T5 alloy. <br />E. Stainless -Steel Sheet: ASTM A 666, Type 304, stretcher -leveled standard of flatness. <br />2.4 FABRICATION <br />A. Fabrication, General: Fabricate toilet compartment components to sizes indicated. Coordinate <br />requirements and provide cutouts for through -partition toilet accessories where required for <br />attachment of toilet accessories. <br />B. Floor -and -Ceiling -Anchored Units: Provide manufacturer's standard corrosion -resistant <br />anchoring assemblies with leveling adjustment nuts at tops and bottoms of pilasters. Provide <br />shoes and sleeves as specified. <br />C. Urinal -Screen Posts: Provide manufacturer's standard corrosion -resistant anchoring assemblies <br />with leveling adjustment nuts at tops and bottoms of posts. Provide shoes and sleeves as <br />specified. <br />D. Door Size and Swings: Unless otherwise indicated, provide 24 -inch wide, in -swinging doors for <br />standard toilet compartments and 36 -inch wide, out -swinging doors with a minimum 32 -inch - <br />wide, clear opening for compartments designated as accessible. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine areas and conditions, with Installer present, for compliance with requirements for <br />fastening, support, alignment, operating clearances, and other conditions affecting performance <br />of the Work. <br />1. Confirm location and adequacy of blocking and supports required for installation. <br />B. Proceed with installation only after unsatisfactory conditions have been corrected. <br />PLASTIC TOILET COMPARTMENTS 10 21 13 - 4 <br />