My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-200C
CBCC
>
Official Documents
>
2010's
>
2014
>
2014-200C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2018 12:10:05 PM
Creation date
10/5/2015 1:22:27 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
12/09/2014
Control Number
2014-200C
Agenda Item Number
12.F.1 (1 of 2 docs)
Entity Name
Kast Construction Company, LLC
Subject
Contract and Document Specifications
Intergenerational Recreation Facility
Area
South County Regional Park
Supplemental fields
SmeadsoftID
14252
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
400
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />constant speeds, PID parameter sets and output Form -C relays. The VFD shall have a <br />digital input that allows an override to the time clock (when in the off mode) for a <br />programmable time frame. There shall be four (4) separate, independent timer functions <br />that have both weekday and weekend settings. <br />4. The VFD's shall utilize pre-programmed application macro's specifically designed to <br />facilitate start-up. The Application Macros shall provide one command to reprogram all <br />parameters and customer interfaces for a particular application to reduce programming <br />time. The VFD shall have two user macros to allow the end-user to create and save <br />custom settings. <br />5. The VFD shall have cooling fans that are designed for easy replacement. The fans shall <br />be designed for replacement without requiring removing the VFD from the wall or removal <br />of circuit boards. The VFD cooling fans shall operate only when required. To extend the <br />fan and bearing operating life, the VFD shall cycle the cooling fans on and off as <br />required. <br />6. The VFD shall be capable of starting into a coasting load (forward or reverse) up to full <br />speed and accelerate or decelerate to set point without tripping or component damage <br />(flying start). <br />7. The VFD shall have the ability to automatically restart after an over -current, over -voltage, <br />under -voltage, or loss of input signal protective trip. The number of restart attempts, trial <br />time, and time between attempts shall be programmable. <br />8. The overload rating of the drive shall be 110% of its normal duty current rating for 1 <br />minute every 10 minutes, 130% overload for 2 seconds. The minimum FLA rating shall <br />meet or exceed the values in the NEC/UL table 430.250 for 4 -pole motors. <br />9. The VFD shall have internal 5% impedance reactors to reduce the harmonics to the <br />power line and to add protection from AC line transients. The 5% impedance may be <br />from dual (positive and negative DC bus) reactors, or 5% AC line reactors. VFD's with <br />only one DC reactor shall add an AC line reactor. <br />10. The input current rating of the VFD shall be no more than 3% greater than the output <br />current rating. VFD's with higher input current ratings require the upstream wiring, <br />protection devices, and source transformers to be oversized per NEC 430.120. Input and <br />output current ratings must be shown on the VFD nameplate. <br />11. The VFD shall include a coordinated AC transient surge protection system consisting of <br />4-120 joule rated MOV's (phase to phase and phase to ground), a capacitor clamp, and <br />5% impedance reactors. <br />12. The VFD shall provide a programmable loss -of -load (broken belt / broken coupling) <br />Form -C relay output. The drive shall be programmable to signal the loss -of -load <br />condition via a keypad warning, Form -C relay output, and / or over the serial <br />communications bus. The loss -of -load condition sensing algorithm shall include a <br />programmable time delay that will allow for motor acceleration from zero speed without <br />signaling a false loss -of -load condition. <br />13. The VFD shall have user programmable underload and overload curve functions to allow <br />user defined indications of broken belt or mechanical failure / jam condition causing <br />motor overload <br />14. The VFD shall include multiple "two zone" PID algorithms that allow the VFD to maintain <br />PID control from two separate feedback signals (4-20mA, 0-10V, and / or serial <br />communications). The two zone control PID algorithm will control motor speed based on <br />a minimum, maximum, or average of the two feedback signals. All of the VFD PID <br />controllers shall include the ability for "two zone" control. <br />15. If the input reference (4-20mA or 2-10V) is lost, the VFD shall give the user the option of <br />either (1) stopping and displaying a fault, (2) running at a programmable preset speed, <br />(3) hold the VFD speed based on the last good reference received, or (4) cause a <br />warning to be issued, as selected by the user. The drive shall be programmable to signal <br />this condition via a keypad warning, Form -C relay output and / or over the serial <br />communication bus. <br />16. The VFD shall have programmable "Sleep" and "Wake up" functions to allow the drive to <br />be started and stopped from the level of a process feedback signal. <br />VARIABLE FREQUENCY MOTOR CONTROLLERS 230514 - 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.