Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />B. Training shall be video taped by a licensed videographer. One DVD copy shall be provided to <br />the owner agent. <br />1.12 MAINTENANCE SERVICE <br />A. Section 01 — Execution and Closeout Requirements: Maintenance service. <br />B. Furnish service and maintenance of variable frequency controller for one year from Date of <br />Substantial Completion. <br />PART 2 - PRODUCTS <br />2.1 VARIABLE FREQUENCY CONTROLLER <br />A. Manufacturers: Subject to compliance with requirements, available manufacturers offering <br />products that may be incorporated into the Work include, but are not limited to, the following: <br />1. ABB. <br />2. Danfoss Inc.; Danfoss Drives Division (Labeled Drives Manufactured by Danfoss Inc. <br />also Permitted) <br />3. Siemens Energy & Automation, Inc. <br />4. Square D; a brand of Schneider Electric. <br />5. Yaskawa Electric America, Inc; Drives Division <br />2.2 VARIABLE FREQUENCY CONTROLLER <br />A. The VFD package as specified herein shall be enclosed in a UL Listed Type enclosure, <br />exceeding NEMA enclosure design criteria (enclosures with only NEMA ratings are not <br />acceptable), completely assembled and tested by the manufacturer in an ISO9001 facility. The <br />VFD tolerated voltage window shall allow the VFD to operate from a line of +30% nominal, and - <br />35% nominal voltage as a minimum. <br />1. Environmental operating conditions: VFDs shall be capable of continuous operation at 0 <br />to 500 C (32 to 1220 F) ambient temperature as per VFD manufacturers <br />documented/submittal data or VFD must be oversized to meet these temperature <br />requirements. Not acceptable are VFD's that can only operate at 40° C intermittently <br />(average during a 24 hour period) and therefore must be oversized. Altitude 0 to 3300 <br />feet above sea level, less than 95% humidity, non -condensing. All circuit boards shall <br />have conformal coating. <br />B. All VFDs shall have the following standard features: <br />All VFDs shall have the same customer interface, including digital display, and keypad, <br />regardless of horsepower rating. The keypad shall be removable, capable of remote <br />mounting and allow for uploading and downloading of parameter settings as an aid for <br />start-up of multiple VFDs. <br />2. The keypad shall include Hand -Off -Auto selections and manual speed control. The drive <br />shall incorporate "bumpless transfer" of speed reference when switching between "Hand" <br />and "Auto" modes. There shall be fault reset and "Help" buttons on the keypad. The <br />Help button shall include "on-line" assistance for programming and troubleshooting. <br />3. There shall be a built-in time clock in the VFD keypad. The clock shall have a battery <br />backup with 10 years minimum life span. The clock shall be used to date and time stamp <br />faults and record operating parameters at the time of fault. If the battery fails, the VFD <br />shall automatically revert to hours of operation since initial power up. Capacitor back-up <br />is not acceptable. The clock shall also be programmable to control start/stop functions, <br />VARIABLE FREQUENCY MOTOR CONTROLLERS 230514 - 4 <br />