Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />2.2 MATERIALS <br />A. VOC Content of Liquid -Applied Flooring Components: Mot more than 100 g/L when <br />calculated according to 40 CFR 59, Subpart D (EPA Method 24): <br />B. Low -Emitting Materials: Flooring system shall comply with the testing and product <br />requirements of the California Department of Health Services' "Standard Practice for the <br />Testing of Volatile Organic Emissions from Various Sources Using Small -Scale Environmental <br />Chambers." <br />2.3 INDUSTRIAL RESINOUS FLOORING <br />A. Resinous Flooring: Abrasion-, impact- and chemical -resistant, industrial -aggregate -filled, resin - <br />based, monolithic floor surfacing designed to produce a seamless floor[ and integral cove <br />base]. <br />B. System Characteristics: <br />1. Color and Patten: As selected by Architect from manufacturer's full range. <br />2. Wearing Surface: Manufacturer's standard wearing surface. <br />3. Overall System Thickness: 1/4 inch (6.4 mm. <br />C. System Physical Properties: Provide resinous flooring system with the following minimum <br />physical property requirements when tested according to test methods indicated: <br />1. Compressive Strength: 7500 psi per ASTM C 579, 7 days. <br />2. Tensile Strength: 1100 psi per ASTM C 307. <br />3. Flexural Modulus of Elasticity: 2600 psi per ASTM C 580. <br />4. Passes Thermal Shock Resistance (ASTM C-884). <br />5. Coefficient of Thermal Expansion: 2 x 10-5 per °F per ASTM C 531. <br />6. Passes Chemical Resistance (ASTM D-1308). <br />7. Impact Resistance: Withstands 16 ft./lbs. with no chipping, cracking, or delamination and <br />not more than 1/16 -inch (1.6 -mm) permanent indentation per MIL -D-3134. <br />8. Resistance to Elevated Temperature: No slip or flow of more than 1/16 inch (1.6 mm) per <br />MIL -D-3134. <br />9. Flammability: Self -extinguishing per ASTM D 635. <br />10. Hardness: 80 - 85, Shore D per ASTM D 2240. <br />11. Bond Strength: 300 psi minimum tensile strength, 100 percent concrete failure per <br />ACI 503R. <br />12. Will not support Fungus & Bacteria Growth per MIL -F-52505. <br />2.4 ACCESSORIES <br />A. Primer: Type recommended by manufacturer for substrate and body coats indicated. <br />B. Patching and Fill Material: Resinous product of or approved by resinous flooring manufacturer <br />and recommended by manufacturer for application indicated. <br />RESINOUS FLOORING 09 67 23 - 3 <br />