Laserfiche WebLink
W All piers over forty (40) inches in height shall <br />be double tiered with blocks interlocked and capped with <br />a 4" x 16" x 16" solid concrete block, or equivalent, and <br />cushioned with wood shims or pressure treated plate. <br />(e) All corner piers over three (3) blocks high <br />shall be double tiered, with blocks interlocked, and <br />capped with a 4" x 16" x 16" solid concrete block, or <br />equivalent, and cushioned with wood shims or pressure <br />treated plate. <br />Section 3. Minimum Anchor Standards. <br />(a) Anchors shall meet the specifications established <br />in -Chapter 15C-1.10 of the Florida Administrative Code. <br />(b) As a minimum standard, anchors shall be installed <br />on both sides of the unit for every twelve (12) feet of <br />trailer length. There shall be a minimum of three (3) <br />regardless of length, with the further requirement that <br />one (1) set shall be on each end. <br />Section 4. Minimum Tie Down Standards. <br />Unless otherwise specified in this section, the tie -down <br />specifications are as follows: <br />(Excluding hitch) <br />Nominal length of Mobile Home <br />Up to 40 to G07 G1 € up —' <br />Single -wide MH Frame ties <br />per side 3 5 7 <br />Single -wide b11I Over---�t;�e-roof - <br />ties -per .side 3 3 3 <br />Single -w) -de 1.111 Number of <br />anchors per <br />side 3 5 7 <br />Double -wide MH Prame ties <br />only per <br />side 3 5 7 <br />-2- <br />'1111. g mis <br />