My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1980-04
CBCC
>
Ordinances
>
1980'S
>
1980
>
1980-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 9:55:35 AM
Creation date
10/5/2015 9:38:31 AM
Metadata
Fields
Template:
Ordinances
Ordinance Number
1980-4
Adopted Date
02/11/1980
Ordinance Type
Building Regulations
State Filed Date
02\08\1980
Entity Name
Board of Adjustments and Appeals
Code Number
79-6 Section 4-110
Subject
Energy Efficiency Code Building Construction
Supplemental fields
SmeadsoftID
12784
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. For A2 buildings U. = 0.38 Max. is permitted. <br />2. Roof/ceiling assemblies in which the finished <br />interior surface is the underside of2theroof deck, <br />a maximum value U is 0.09 BTU/h ft. F." <br />(i) Add the following EQUATION 1-A on a new page of the <br />energy code numbered 5-6.1: <br />"EQUATION 1-A <br />UO = M x UwAw + UgAg + UdAd <br />A <br />WHERE: <br />UO = the average or combined thermal transmittance of the <br />(j) Add the following Table 5-2C after Table 5-2B at page <br />5-8 of the energy code: <br />"TABLE 5-2C <br />Insulating/Solar Glass Equivalence <br />gross exterior wall area. <br />A = the gross exterior wall area. <br />Uw = the thermal transmittance of the opaque wall. <br />Aw =opaque wall area <br />Ug = the thermal transmittance of the glazing. <br />= glazing area. <br />Equivalent Shading Coefficients <br />Climatological Zones <br />1 2 3 4 5 6 7 8 9 <br />0.55 0.55 0.58 0.64 0.63 0.66 0.68 0.70 0.70 <br />After calculating compliance of U values, the designer <br />may substitute equal amounts of solar glass with the above <br />shading coefficients (or lower) for insulating glass with <br />U values of 0.65 (or higher)." <br />(k) Paragraph 503.2(a) at page 5-10 of the energy code is <br />hereby amended as follows: <br />"503.2 (a) Calculation Procedures. For purposes of sizing <br />HVAC systems, the procedures described in <br />Chapters 24, 25, or 26 of Std. RS -1 may be <br />used, or an equivalent computation procedure. <br />Ag <br />Ud <br />= the thermal transmittance <br />of the <br />doors. <br />Ad <br />=door area. <br />M <br />= correction factor for mass <br />based <br />on specific heat, <br />density and climate." <br />Equivalent Shading Coefficients <br />Climatological Zones <br />1 2 3 4 5 6 7 8 9 <br />0.55 0.55 0.58 0.64 0.63 0.66 0.68 0.70 0.70 <br />After calculating compliance of U values, the designer <br />may substitute equal amounts of solar glass with the above <br />shading coefficients (or lower) for insulating glass with <br />U values of 0.65 (or higher)." <br />(k) Paragraph 503.2(a) at page 5-10 of the energy code is <br />hereby amended as follows: <br />"503.2 (a) Calculation Procedures. For purposes of sizing <br />HVAC systems, the procedures described in <br />Chapters 24, 25, or 26 of Std. RS -1 may be <br />used, or an equivalent computation procedure. <br />