Laserfiche WebLink
determined by FM 1-T 257 and by averaging the test results for three randomly <br /> selected samples from each stratum or stockpile of a particular material, shall not be <br /> used in construction of the reinforced volume. If an individual test value of the three <br /> samples exceeds 3.0%, the stratum or stockpile will not be suitable for construction of <br /> the reinforced volume. <br /> No A-8 material permitted in embankment. <br /> E. Payment shall be made under: <br /> Bid Item No. 120-1 -- Excavation, Regular (Roadway) — Per Cubic Yard <br /> Bid Item No. 120-5 - Embankment Spreading and Finish Grade of in Place fill <br /> material (Compacted in Place) - Per Cubic Yard <br /> SECTION -160 - STABILIZATION <br /> A. Sub Article 150-5.1 is modified by the addition of the following: <br /> "The stabilization thickness indicated on plans shall be considered a minimum <br /> thickness. Thickness will vary to conform to the lines, and grades shown in the plans," <br /> Minimum L.B.R. = 40 - No under-tolerance. <br /> B. Payment shall be made under; <br /> Bid Item No. 150--4-12 -- Type B Stabilization LBR40 (12") -- Per Square Yard <br /> SECTION - 425 — INLETS MANHOLES AND JUNCTION BOXES <br /> The work specified in this item shall conform to Section 425 of the Florida Department of <br /> Transportation Standard Specifications for Road and Bridge Construction (2010). <br /> ,Item of Payment <br /> Payment for the work specified in this item shall be made under: <br /> Bid Item No. 425--1--521 - Inlets (Ditch Bottom) (Type C) (<10') - Per Each <br /> SECTION - 430 — PIPING <br /> The work specified in this item shall conform to Section 430 of the Florida Department of <br /> Transportation Standard Specifications for Road and Bridge Construction (2010). <br /> Item of Payment <br /> Payment for the work specified in this item shall be made under: <br /> Bid Item No. 430-171-125 —Aluminized Corrugated Metal Pipe (18") Per Linear Foot <br /> Bid Item No. 430-982-125 — Mitered End Section (18") Per Each <br /> 01025-19 Technical Specifications <br /> FAP ubIic Wo rks\E NG I N E E R I NG DIVISION PRGJECTS11210-Sandridge Driving Range Tee RenovationlAdmimlbid documents\TechnicaI <br /> Specifications.doc <br /> SmeadSoft Reprint Date:Monday,January 11,2016-09:22:25-OfficialDocuments:9069,Attachment Id 1,Page 179 <br />