My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-241A
CBCC
>
Official Documents
>
2010's
>
2015
>
2015-241A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2017 10:04:20 AM
Creation date
1/11/2016 11:38:37 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
12/15/2015
Control Number
2015-241A
Agenda Item Number
8.L.
Entity Name
West Construction Inc.
Subject
Contrac and Specifications
Skeet and Trap Facility Improvements
Indian River Count Public Shooting Range
Area
Indian River County Public Shooting Range
Project Number
1213B
Bid Number
2016008
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 08360 - SECTIONAL OVERHEAD DOORS <br />PART 1 GENERAL <br />1.1 SECTION INCLUDES <br />A. Steel Sectional Overhead Doors. <br />B. Electric Operators and Controls. <br />C. Operating Hardware, tracks, and support. <br />1.2 RELATED SECTIONS <br />A. Section 03300 - Cast -In -Place Concrete: Prepared opening in concrete. Execution requirements for <br />placement of anchors in concrete wall construction. <br />B. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry. Execution requirements for <br />placement of anchors in masonry wall construction. <br />C. Section 05500 - Metal Fabrications. Steel frame and supports. <br />D Section 07900 - Joint Sealers: Perimeter sealant and backup materials. <br />E. Section 09900 - Paints and Coatings: Field painting. <br />F. Section 16130 - Raceway and Boxes: Empty conduit from control station to door operator <br />G. Section 16150 - Wiring Connections. Electrical service to door operator <br />1.3 REFERENCES <br />A. ANSI/DASMA 102 - American National Standard Specifications for Sectional Overhead Type Doors. <br />1.4 DESIGN / PERFORMANCE REQUIREMENTS <br />A. Wind Loads: Design and size components to withstand loads caused by pressure and suction of wind <br />acting normal to plane of wall as calculated in accordance with applicable code. <br />1 Design pressure as noted on the Structural Drawings. <br />2. Impact Test for Flying Debris: Comply with ASTM E 1996, tested according to <br />ASTM E 1886. <br />a. Level of Protection: Enhanced Protection. <br />B. Wiring Connections: Requirements for electrical characteristics. <br />1 115 volts, single phase, 60 Hz. <br />2. 230 volts, single phase, 60 Hz. <br />C. Single -Source Responsibility: Provide doors, tracks, motors, and accessories from one manufacturer <br />for each type of door. Provide secondary components from source acceptable to manufacturer of <br />primary components. <br />1.5 SUBMITTALS <br />A. Submit under provisions of Section 01300. <br />Indian River County Skeet and Trap 08630 — 1 <br />DAA Project No. 2013.04 11/12/15 Bid Set — ADDENDUM #1 <br />