Laserfiche WebLink
Intergenerational Recreation Center Page -6- <br />AACE Proposal No. P14-392 <br />The following conditions apply to this project: <br />(1) A minimum of 4 density tests or 1 set of concrete testing will need to be performed per hour, per visit to the site. <br />(2) Stand-by time will be charged at $55.00/hour per technician. <br />(3) We note that density testing frequencies are approximate and based on our experience with similar projects and <br />anticipated contractor methodologies. Allowances for re -tests (from failing density tests) are not included herein. <br />(4) The contractor should contact Andersen Andre Consulting Engineers, Inc. at (772) 807-9191 a minimum of 24 <br />hours prior to any testing and 48 hours pnor to weekend and evening work. <br />Unit rates apply to standard working days, Monday through Friday, 7:00 a.m to 6:00 p.m. Testing and hourly rates <br />will be increased by 50% for weekend, holiday or after-hours services. <br />(5) <br />(6) The following testing costs are not included within this estimate: costs associated with asphalt testing (either in the <br />field or laboratory) or bacteriological testing of potable water (bac-t's). Such testing can be performed if requested <br />using the rates included herein. <br />(7) <br />If our testing estimate for a specific work element is insufficient for that particular activity, resources from another <br />work element can be used without prior authorization from the client as long as our total cost esumate is not <br />exceeded. We will notify you in advance if it appears that the cost estimate presented in the attached unit fee <br />schedule will be exceeded. <br />(8) Soil sample pickup for laboratory testing (e.g., Proctor testing) will be billed at $55.00/hour if not scheduled with <br />other work. <br />(9) <br />We note that the number of sets of concrete cylinders is dependent on numerous factors, such as the size and <br />duration of pours. For example, if numerous "smaller" pours (e.g., 10 -yard pours) occur during construction, our <br />estimate for the number of sets of concrete cylinders may be exceeded, thus requiring revision of this proposal to <br />account for this testing cost increase. <br />(10) No paint -thickness or fire proofing thickness testing, bolt -tightness, steel or weld inspections, or floor levelness <br />testing are included herein; we would be pleased to revise this proposal to include such services if requested. <br />