Laserfiche WebLink
An 21 1989 <br />5. Total Impervious Area: 144 square feet <br />6. Open Space Required: 50% <br />Provided: 95.6% <br />600K. 78 ME. 418 <br />7. Traffic Circulation: The tower site will be accessed through <br />the existing parking lot for the Central Assembly of God <br />Church. <br />8. Off -Street Parking Required: one space <br />Provided: one space <br />9. Stormwater Management: The Stormwater Management Plan has <br />been approved by the Public Works Department. <br />10. Landscape Plan: The landscape plan is in conformance with <br />Ordinance #84-47. <br />11. Utilities: This project will require no sanitary services. <br />12. Special Exception Criteria: <br />a. A11 towers shall have setbacks from all property lines <br />equal to one hundred ten (110) per cent of the height of <br />the proposed structure, or a designated fall radius must <br />be depicted on the site plan and certified by a P.E. <br />b. A certified, signed and sealed statement from a Florida <br />Registered Professional Engineer must state that the <br />tower would collapse within the designed and specified <br />fall radius depicted on the plans. <br />c. In no case shall the fall radius (110% of height or <br />other approved design fall radius) encroach upon exist- <br />ing off-site structures or residentially zoned property. <br />d. The distance of any guy anchorage or similar device <br />shall be at least ten (10) feet from any property line. <br />e. Suitable protective anti -climb }fencing and a landscape <br />planting screening shall be provided and maintained <br />around the structure and accessory attachments. Where <br />the first 50' of a tower is visible to the public, the <br />applicant shall provide one canopy tree (oak, pine, <br />etc.) per 3,000 square feet of the designated fall <br />radius. <br />f. A11 accessory structures shall be subject to the height <br />restrictions provided in Section 25(a), height ex- <br />ceptions. <br />g• <br />If more than two hundred twenty (220) voltage is neces- <br />sary for the operation of the facility and is present in <br />a ground grid or in the tower, signs located every <br />twenty (20) feet and attached to the fence or wall shall <br />display in large bold letters the following: "HIGH <br />VOLTAGE - DANGER." <br />h. No equipment, mobile or immobile, which is not used in <br />direct support of the transmission or relay facility <br />shall be stored or parked on the site unless repairs to <br />the facility are being made. (Applies only on A-1 zoned <br />property.) <br />i. No tower shall be permitted to encroach into or through <br />any established public or private airport approach plan <br />as provided in the airport height limitations of Section <br />25(p). <br />j <br />All towers shall submit a conceptual tower lighting <br />plan. Louvers or shields may be required as necessary <br />to keep light from shining down on surrounding prop- <br />erties. Strobe lights must be used unless prohibited by <br />other agencies. <br />18 <br />