Sewerage Facilities <br /> Concrete (Wet Wells, Tanks, Submerged or Severe Conditions ------ Color – Series 46-413 Coal Tar <br /> Channels,etc.) Ri ortex 3324 Enamel 104--------Series 104 <br /> Metal (Equipment, Piping Systems, Submerged, or Intermittently Submerged, or Primer Series 661211— <br /> Tanks,etc.) Extreme Conditions Finish 46-413 (2 coats, 8 <br /> mil. ea.)-46H (1 coat, 16 <br /> mil. <br /> Metal(moving Parts–Chains, Gates, Submerged or Intermittently Submerged Grease Coating <br /> etc. <br /> Water Facilities <br /> Concrete (Tanks, Troughs, Basins, Submerged, or Intermittently Submerged Primer Series 20-1255, <br /> etc.) Beige 3-5 mil – Filler <br /> Series 63 – 1500, as <br /> applicable –Finish Series <br /> 20-13682,4-6 mils <br /> Metal (Tanks, Piping Systems, Submerged, or Intermittently Submerged Primer Series 20- 1255, <br /> Equipment) Beige 3-5 mil – Filler <br /> Series 63 – 1500, as <br /> applicable –Finish Series <br /> 20-BB82,4-6 mils <br /> Special Notes: <br /> 1. All galvanized or other nonferrous surfaces requiring painting shall be pretreated with an approved <br /> conditioner or passivator, as recommended by the paint manufacturer, prior to application of the painting <br /> system. <br /> 2. Bituminous coated pipe shall be coated with Inertol Tar Stop or approved equal, as recommended prior <br /> to application of the painting system. <br /> 3. Metal surfaces, in contact with concrete or masonry, shall be protected with Tnemec46-413 Coal Tar <br /> coating or approved equal, as recommended. This provision shall not apply to concrete reinforcement, <br /> piping and fittings,or conduits and accessories. <br /> 16.05 ELECTRIC <br /> A. General <br /> The provisions of this Section, including other specific design <br /> considerations, shall be the minimum standards as applicable to all <br /> sewage and water facilities. <br /> It shall be the responsibility of the Contractor to advise the <br /> appropriate electrical power company regarding the proposed facility <br /> prior to installation and to make the necessary provisions for service <br /> thereto. <br /> In accordance with the provisions of the General Conditions, <br /> complete shop drawings and technical data shall be submitted to the <br /> IRCDUS including, but not limited to, motor control centers and <br /> control systems, with wiring diagrams and components; <br /> manufacturer's data for switches, transformers, relays, lighting <br /> fixtures and other accessories; panel boards; and all other applicable <br /> information. <br /> B. Materials, Equipment and Installation <br /> 16-14 1 �3.Q.IS�• <br />