Laserfiche WebLink
PREPARED FOR: <br /> Sprint= <br /> 1 INTERNATIONAL BOULEVARD <br /> SUITE #500 <br /> MAHWAH, N.J. 07495 <br /> CONSULTANT: ■MM..'' <br /> ■LH <br /> M°ORRISON HERSHFIELD <br /> UMwnq Dbw,Su 245. <br /> FLnbOm.FL 55]21 <br /> Tet 931.SPA355 Fet B51.5T2.4858 <br /> STAT!OF FLORNA Cd 0000350! <br /> w"wmornwnMnenOeM.aom <br /> SITE NAME: <br /> GIFFORD WATER TANK <br /> SITE NUMBER: <br /> M160XC240 <br /> SITE ADDRESS: <br /> 4690 28TH CT. <br /> VERO BEACH,FLORIDA 32948 <br /> IAN RIVER COUNTY <br /> ALARM WIRING SCHEMATICS M g <br /> Q` re2�1 �.aunuLn, <br /> ERICSSON MM-BTS RBS 6102 CONTACT SEVERITY OWNER COMMENTS COLOR CODE Q 2Vnj, ,.V''A <br /> C <br /> BTS SCAN POINT 1 110001 UTILITY POWER FAILURE NC MAJOR SERVICE ASSURANCE RBS/RIGHT OVP1/A4 WHITE/BLUE ° C E <br /> BTS SCAN POINT 2112001 GENERATOR FAILURE NC MINOR FIELD SERVICES RBS/RIGHT OVP1/A5 WHITE/ORANGE N0. 62209 <br /> BTS SCAN POINT 3 112011 GENERATOR RUNNING NC MINOR DRMS ONLY RBS/RIGHT OVP1/A6 WHITE/GREEN <br /> STATE OF <br /> BTS SCAN POINT 4 112021 GENERATOR LOW FUEL THRESHOLD REACHED NC MAJOR FIELD SERVICES R85/RIGHT OVP1/A7 WHITE/BROWN 'per°, <br /> NC MAJOR SERVICE ASSURANCE RBS/RIGHT OVPI/AS WHITE/SLATE OR IOP°"` <br /> 41 <br /> B75 SCAN POINT 5 190001 TOWER TDP LIGHT FAILURE, NOTAM REQUIRED <br /> BTS SCAN POINT 6 191001 TOWER SIDE LIGHT FAILURE, NO NOTAM NC MINOR SERVICE ASSURANCE RBS/RIGHT OVP2/A2 RED/BLUE <br /> BTS SCAN POINT 7 120081 1900 #1 DBU FAN FAILURE (CABLE SUPPLIED INTERNAL) NC MAJOR FIELD SERVICES RBS/RIGHT OVP2/A3 WHITE/BROWN <br /> BTS SCAN POINT 8 120081 1900 #2 DBU FAN FAILURE (CABLE SUPPLIED INTERNAL) NC MAJOR FIELD SERVICES RBS/RIGHT OVP2/At WHITE/BROWN <br /> REGISTERED ER[:NEER <br /> BTS SCAN POINT 9120081 800 DBU FAN FAILURE (CABLE SUPPLIED INTERNAL) NC MAJOR FIELD SERVICES RBS/LEFT OVPI/A1 WHITE/BROWN Sr",E;,?�°"1D" <br /> BTS SCAN POINT 10 USER DEFINED FROM STANDARDS COLUMN A ONLY NC RBS/RIGHT OVPI/AB RED/ORANGE <br /> BTS SCAN POINT 11 USER DEFINED FROM STANDARDS COLUMN A ONLY NC RBS/RIGHT OVP2/A4 RED/GREEN <br /> BTS SCAN POINT 12 USER DEFINED FROM STANDARDS COLUMN A ONLY NC RBS/RIGHT OVP2/A5 RED/BROWN rDRAWN BY:WJDATE DRAWN:05/12/12 <br /> BTS SCAN POINT 13 USER DEFINED FROM STANDARDS COLUMN A ONLY NC RBS/RIGHT OVP2/A6 REO/SLATE <br /> REVIEWED BY: CC APPROVED BY: RL <br /> BTS SCAN POINT 14 USER DEFINED FROM STANDARDS COLUMN A ONLY NC RBS/RIGHT OVP2/A7 BLACK/BLUE MH PROJECT#:7123001.00 <br /> BTS SCAN POINT 15 CLIMATE ALARM BBS 6102 (CABLE SUPPLIED) NC FIELD SERVICES RBS/RIGHT OVP1/A2 RED/ORANGE REVISION <br /> NO DESCRIPTION BY DATE <br /> BTS SCAN POINT 16 OPEN DOOR BBS 6102 (CABLE SUPPLIED) NC FIELD SERVICES RBS/RIGHT OVP1/A1 BLACK/BROWN A 90f.CD SUBMITTAL wJ 05/14/12 <br /> 0 FINAL HU07 25/12 <br /> 1 FINAL WJ 09'ZZ' <br /> 27 12 <br /> • NC - NORMALLY CLOSED(CLOSED CONTACTS WITH NO ALARM CONDITION) 2 U.S.G. COMMENTS CA 26/12/11 <br /> SHEET TITLE: <br /> .� ALARM WIRING SCHEMATICS ALARM WIRING SCHEMATICS <br /> N.T.S. <br /> SHEET NUMBER: <br /> E-6 <br />