Laserfiche WebLink
r <br />I <br />PUUK. P,G r 66 <br />Segment <br />Roadway <br />Segment <br />Road <br />Total <br />From <br />To <br />Capacity <br />LOS "D" <br />3010 <br />58th <br />Ave. <br />4th St. <br />8th St. <br />630 <br />3015 <br />58th <br />Ave. <br />8th St. <br />12th St. <br />630 <br />3020 <br />58th <br />Ave. <br />12th St. <br />16th St. <br />630 <br />3025 <br />58th <br />Ave. <br />16th St. <br />S.R. 60 <br />830 <br />3030 <br />58th <br />Ave. <br />S.R.'60 <br />41st St. <br />830 <br />3310 <br />82nd <br />Ave. <br />Oslo Rd. <br />4th St. <br />630 <br />3320 <br />82nd <br />Ave. <br />4th St. <br />12th St. <br />630 <br />3330 <br />82nd <br />Ave. <br />12th St. <br />S.R. 60 <br />630 <br />3340 <br />82nd <br />Ave. <br />S.R. 60 <br />65th St. <br />630 <br />Existing <br />Demand <br />Total <br />Available <br />Positive <br />Roadway Existing <br />Vested <br />Segment <br />Segment <br />Project Concurrency <br />Segment Volume <br />Volume <br />Demand <br />Capacity <br />Demand Determination <br />2530 <br />162 <br />3 <br />165 <br />465 <br />37 Y <br />2540 <br />162 <br />8 <br />170 <br />460 <br />13 Y <br />2550 <br />265 <br />19 <br />284 <br />346 <br />8 Y <br />2560 <br />265 <br />32 <br />297 <br />533 <br />6 Y <br />2570 <br />360 <br />41 <br />401 <br />429 <br />4 Y <br />2580 <br />414 <br />37 <br />451 <br />379 <br />4 Y <br />2910 <br />225 <br />2 <br />221 <br />403 <br />5 Y <br />2915 <br />360 <br />0 <br />360 <br />270 <br />4 Y <br />2920 <br />454 <br />0 <br />454 <br />176 <br />4 Y <br />2925 <br />454 <br />1 <br />455 <br />375 <br />4 Y <br />2930 <br />373 <br />1 <br />374 <br />456 <br />4 Y <br />3005 <br />144 <br />9 <br />153 <br />477 <br />12 Y <br />3010 <br />144 <br />6 <br />150 <br />480 <br />10 Y <br />3015 <br />144 <br />6 <br />150 <br />480 <br />8 Y <br />3020 <br />144 <br />21 <br />165. <br />465 <br />8 Y <br />3025 <br />400 <br />20 <br />420 <br />410 <br />8 Y <br />3030 <br />414 <br />29 <br />443 <br />387 <br />4 Y <br />3310 <br />162 <br />1 <br />163 <br />467 <br />15 Y <br />3320 <br />162 <br />2 <br />164 <br />466 <br />10 Y <br />3330 <br />162 <br />9 <br />171 <br />459 <br />8 Y <br />3340 <br />45 <br />7 <br />52 <br />578 <br />2 Y <br />-Water <br />The site is located within the south county Water Service Area; <br />however, water lines do not currently extend to the site. With the <br />most intense use under the. proposed zoning designation, the subject <br />property will have a consumption rate of 13.74 Equivalent <br />Residential Units (ERUs), or 3,435 gallons per day. This is based <br />upon the level of service of 250 gallons per ERU per day. Since no <br />ERUs have been reserved as of the present time, the applicant has <br />entered into a developer's agrejement.with the county which states <br />that the developer agrees to pay his impact fees and connect to the <br />county system if capacity is available at the time of development <br />or to expand county water facilities or pay for the expansion if <br />capacity is not available at the time of site development. This is <br />consistent with Future Landi Use Polfcy .2.7 which requires <br />development projects to maintain established levels of service. <br />-Wastewater <br />A retail commercial use of 45,800 square feet on the subject <br />property will have a wastewater generation rate of 13.74 Equivalent <br />Residential Units (ERUs), or 3,435 gallons per day. This is based <br />-- ! upon the county's adopted level of service standard of 250 gallons <br />per ERU per day. County wastewater service is available to the <br />site from the West County Wastewater Plant. Since no ERUs have <br />been reserved as of the presenjt time, the applicant has entered <br />into a developer's agreement with the county which states that the <br />developer agrees to pay his impact fees and connect to the county <br />system if capacity is available at the time of development or to <br />expand county wastewater facilities or pay for the expansion if <br />capacity is not available at the time of site development. With <br />316 <br />M 0 M <br />