Laserfiche WebLink
SECTION 00310 - Bid Form <br /> PROJECT IDENTIFICATION- <br /> Project Name I R.0 GO LINE TRANSFER HUB <br /> County Project Number 1330 <br /> Bid Number 2016019 <br /> Project Address. 16th Street East of Old Dixie Highway <br /> Vero Beach, FL 32960 <br /> Project Description <br /> 1. The construction of one enclosed/partially enclosed habitable single story <br /> structure, several exterior roof covered pre-manufactured structures, and all <br /> associated site work <br /> a. 1,732 SF single story structure (the "Primary Building Structure") <br /> constructed with a concrete slab on grade with a monolithic concrete foundation, <br /> concrete block masonry walls and pre- engineered wood roof trusses. All <br /> architectural design has been provided by IRC (Owner). <br /> b. 3,410 SF+/- (as measured to exterior of columns) exterior roof covered, pre- <br /> manufactured building structure(s) (the "Exterior Shelter Structures'9 approximately <br /> 10FT+/- width and with a total length of 330 FT +/-, lying in an irregular / non- <br /> linear shape. Preliminary architectural design has been provided by Owner. The <br /> building system design shall be signed and sealed by a Florida Licensed architect <br /> and/or engineer as required by the Building Department and provided by the <br /> contractor The building system shall be a complete system and shall include <br /> the requisite foundation system, structural metal/aluminum framing system, flat <br /> metal roof panels where indicated, and sloped metal roofing system to <br /> match the primary building where indicated on the plans, together with <br /> flashing trim, fascia, gutters and downspouts, and decorative architectural <br /> features as depicted on the conceptual plans to match the architectural style, <br /> color, materials, and textures of the primary building These features shall <br /> include but may not be limited to decorative columns, fascia, sloped roof, and <br /> exposed rafters. The engineer and architect of record for this project provided by <br /> Owner must review and approve the shop drawings for the building system prior to <br /> the issuance of a building permit The design shall be substantially in <br /> conformance with the preliminary architectural plans provided in the contract <br /> documents/plans. Mechanical, electrical, and plumbing engineering and <br /> preliminary architecture design has been provided for this building by Owner but <br /> is subject to revisions <br /> c. Site improvements for the 1.60 +/--acre site development area, together with <br /> 'off-site"improvements in 16th Street. The site improvements include all <br /> clearing, earthwork, paving, drainage, and utilities, sidewalks, landscaping, <br /> irrigation systems, and all other site construction work listed or described in <br /> the contract documents/plans and site development permits. <br /> 00310-1 <br />