My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-122A
CBCC
>
Official Documents
>
2010's
>
2014
>
2014-122A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/13/2017 2:28:12 PM
Creation date
1/10/2017 10:00:03 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Correspondence
Approved Date
09/09/2014
Control Number
2014-122A
Agenda Item Number
8.U.
Entity Name
Dickerson Florida Inc.
Subject
Contract and Specifications
13th St. SW at 58th Ave. Bridge
Area
13th St. SW
Project Number
0530B
Bid Number
2014046
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The determination of the amount of residual chlorine in the system shall be <br />made at such points and in accord with standard tests by means of a <br />standard orthotolodine test set. <br />3.04 BACTERIOLOGICAL SAMPLING <br />A. It shall be the responsibility of the Contractor under this contract to perform the <br />bacteriological testing required by the Florida Department of Environmental <br />Protection and Indian River County to obtain clearance of the water main <br />piping. The Contractor shall be responsible to disinfect and repeat testing as <br />needed until clearance is obtained for all required plant systems. The <br />Contractor shall be responsible to pay for additional water needed if the <br />bacteriological testing must be repeated for the clearance of the ground <br />storage tank. <br />B. The piping systems require two (2) consecutive daily samples taken from the <br />locations called out on the plans or as determined by the Engineer. The <br />samples shall be taken at all the respective sample point locations. <br />C. Sampling must be coordinated with Engineer and other construction activities <br />so as to minimize re -sampling. <br />D. Contractor shall submit schedule for bacteriological testing and pressure tests. <br />E. The Contractor shall incur all costs needed to provide bacteriological clearance <br />of the piping systems. <br />3.11 QUALITY CONTROL <br />A. The laboratory and personnel collecting bacteriological samples shall be <br />Florida State certified in accordance with FDEP requirements. <br />+ + END OF SECTION + + <br />01025-36 Technical Specifications <br />F•\Public Works\ENGINEERING DIVISION PROJECTS\05306 13th Street SW at 58th Ave Bridge\Admin\bid documents\Master <br />Contract Documents\Technical Specifications.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.