Laserfiche WebLink
i <br /> ill <br /> i <br /> PUMP / LIFT STATION: <br /> i <br /> Record Drawings shall show elevations for the top and bottom and diameter of wet well <br /> along with invert of effluent line. Record Drawings should also indicate the make, model <br /> number, horsepower, impeller and condition point of pumps selected and installed, shape <br /> of wet well, location of control panel, location of pump out connection, float level settings, <br /> any deviation from the plans, and serial number(s) of the pump(s). i <br /> SURVEY CONTROL I <br /> 1. Install/re-establish: -It shall be the contractor's responsibility to hire a Professional <br /> Surveyor and Mapper as defined per Chapter 472, Florida Statutes, to replace any <br /> horizontal and vertical control shown on the engineering plans that was destroyed <br /> during construction. <br /> 2. New roadway alignment control points (survey baseline or controlling line and all points <br /> as indicated on the plans or control sheet) upon final roadway completion. Include all <br /> intersections and side streets. State plane coordinates and elevations for all control <br /> points. <br /> 3. If shown on plans or not: Any Public Land Corner or Governmental Survey Control <br /> point(s),vertical control (bench marks), property corners destroyed and/or disturbed <br /> during the scope of the project shall be properly re-established as per standards as set <br /> forth within Florida Statutes,Administrative code and Minimum Technical Standards for <br /> that type of survey. All said surveying mentioned above shall be performed under the j <br /> direct supervision of a registered Professional Surveyor and Mapper in the state of <br /> Florida and certified accordingly. Said Governmental agency(s) shall be notified in <br /> writing of disturbance and re-establishments. <br /> RECORD/AS-BUILTS DRAWINGS FORMAT - SUBMITTAL i <br /> A. ENGINEER will supply the CONTRACTOR with the electronic file of the <br /> approved construction plans for the input of the As-Built (record) information. <br /> B. CONTRACTOR shall deliver seven (7) certified sets of Record/As-Builts with <br /> Electronic Drawing files prepared in AutoCad Civil 3D 2013 AND PDF format or <br /> ._..incurrent version-as-agreed-b_y_the_ENGINEER.. ____ __ __. __ _ - _ <br /> C. CONTRACTOR's surveyor shall review, sign and seal As-Builts or Record <br /> drawing(s). Said drawing(s) shall clearly state type of survey, positional <br /> tolerances, adhere and be certified to by a registered Professional Surveyor and ! <br /> Mapper in the state of Florida, any standards set forth by Florida Statutes, <br /> Administrative code and Minimum Technical Standards for As-Built/Record <br /> surveys. <br /> D. All Record/As-Built drawings are subject to review and approval by County <br /> Surveyor. <br /> I <br /> i <br /> 01025-5 <br /> Technical Specifications <br /> P\Public Works\ENGINEERING DIVISION PROJECTS\1123 43rd Ave Sidewalk Improvements 26th St.to Airport Dr <br /> West\AdmimUd documents\Master Contract Documents\Technical Specifications.doc <br /> i <br />