My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-054
CBCC
>
Official Documents
>
2010's
>
2017
>
2017-054
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2017 10:29:50 AM
Creation date
4/20/2017 10:29:49 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
04/18/2017
Control Number
2017-054
Agenda Item Number
8.D.
Entity Name
Kimley-Horn and Assoc.
Subject
Work Order No. 13
Roseland Elevated Tank
Conversion to Repump Station
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Consultant will prepare 60%and 100% final design of a booster pump station for review by <br /> IRCU. <br /> Consultant will prepare technical specifications for the site,piping,transfer pump station, <br /> landscaping and pond. Consultant will prepare 60%and 100%review sets for Owner review. <br /> Consultant will provide four(4)printed hard copies of each and electronic version in Adobe.pdf, <br /> MSWord, and AUTOCadd 2014 format of final documents. <br /> Consultant will prepare an opinion of probable construction costs for the pump station, <br /> consisting of the booster pump station, influent piping and control valve station to the storage <br /> tanks,pump station(pumps,piping, valves, electrical,civil,controls),distribution piping tie-in to <br /> existing watermain, electrical and controls including local and distributed control via the IRCU <br /> SCADA system. <br /> Consultant will prepare an opinion of probable construction costs based on final drawings and <br /> specifications. <br /> Task 3—ELECTRICAL DESIGN <br /> Consultant's subconsultant, C&W Engineering Consultants.(C&W),will prepare electrical and <br /> instrumentation engineering design associated with the booster pump station. The system is <br /> assumed to be designed based on the following: <br /> • Electrical improvements including motor starters in existing master pump station <br /> electrical room,PLC and control panel modifications <br /> • Two (2)60 hp,or.three(3)40150 HP booster pumps,rated for 480V 3-phase power, <br /> driven by VFD's <br /> • Inlet control valve with flow meters and inlet/outlet pressure monitors <br /> • Level monitoring in tank <br /> • A new remote PLC within the MCP shall be utilized for control and operation of the new <br /> pumps and instruments <br /> Consultant will visit the site and observe existing electrical service and space for new electrical <br /> gear and control cabinets. C&W shall assist with building department permitting process and <br /> answer a reasonable number of questions resulting from building department review. <br /> Consultant will prepare electrical design drawings consisting of electrical site plan, single line <br /> diagrams,control panel schematics, and details for a new booster pump station being powered <br /> and controlled via VFD's and PLC control system. <br /> Task 4—PERMITTING <br /> The Consultant will prepare and submit an FDEPpen-nit application 62-555.900(l)for the <br /> proposed pump station,generator,and electrical improvements,including a permit application <br />