My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-062A
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-062A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2020 10:08:58 AM
Creation date
4/25/2018 4:40:43 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
04/03/2018
Control Number
2018-062A
Agenda Item Number
8.E.
Entity Name
Indian River County Jail Complex
Subject
Roofing replacement, recover, and repair project
Project Number
IRC-1735
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOFING REPLACEMENT, RECOVER AND REPAIR PROJECT PAGE 1 <br />INDIAN RIVER COUNTY - JAIL COMPLEX SECTION 076200 <br />JANUARY 4, 2018 SHEET METAL FLASHING AND TRIM <br />SECTION 076200 - SHEET METAL FLASHING AND TRIM <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />A. Drawings and general provisions of the Contract, including General and Supplementary <br />Conditions and Division 1 Specification Sections, apply to this Section. <br />1.2 SUMMARY <br />A. This Section includes the following sheet metal flashing and trim: <br />1. Formed steep -slope roof flashing and trim. <br />B. Related Sections include the following: <br />1. Division 6 Section 061000 "Rough. Carpentry" for wood nailers; and wood <br />battens. <br />2. Division 7 Section 079200 "Joint Sealants" for field -applied sheet metal flashing <br />and trim sealants. <br />1.3 PERFORMANCE REQUIREMENTS <br />A. General: Install sheet metal flashing and trim to withstand wind loads, structural <br />movement, thermally induced movement, and exposure to weather without failing, <br />rattling, leaking, and fastener disengagement. <br />B. Fabricate and install roof edge flashing capable of resisting the following forces <br />according to recommendations in FMG Loss Prevention Data Sheet 1-49: <br />C. Thermal Movements: Provide sheet metal flashing and trim that allow for thermal <br />movements resulting from the following maximum change (range) in ambient and <br />surface temperatures by preventing. buckling, opening of joints, hole elongation, <br />overstressing of components, failure of joint sealants, failure of connections, and other <br />detrimental effects. Provide clips that resist rotation and avoid shear stress as a result <br />of sheet metal and. trim thermal movements. Base engineering calculation on surface <br />temperatures of materials due to both solar heat gain and nighttime -sky heat loss. <br />1. Temperature Change (Range): 120. deg F (67 deg C), ambient; 180 deg F (100 <br />deg C), material surfaces. <br />D. Water Infiltration: Provide sheet metal flashing and trim that do not allow water <br />infiltration to building interior. <br />
The URL can be used to link to this page
Your browser does not support the video tag.