Laserfiche WebLink
ORDER NO. PSC -2018 -0316 -PAA -EQ <br />DOCKET NO. 20180083 -EQ <br />PAGE 10 <br />FLORIDA POWER & L1GlIT COMPANY <br />(Continued from Sheet No. 9.032) <br />3:2 QS, at no cost to FPL, shall be responsible to: <br />Attachment A <br />First Revised Sheet No. 9.032.1 <br />Cancels Original Sheet No. 9.032.1 <br />32.1 Design, construct, and maintain the Facility in accordance with this Contract, applicable law, regulatory, and <br />governmental approvals, any requirements of warramty agreements or similar agreements, prudent industry practice, <br />insurance policies, and the Interconnection Agreement or Wheeling Agreement. <br />32.2 Perform all studies, pay all fees, obtain all necessary approvals and execute all necessary agreements (including <br />the Interconnection Agreement or the Wheeling Agreement(s)) in order to schedule and deliver the firm capacity and <br />energy to FPL <br />3.2.3 Obtain and maintain all permits, certifications, licenses, consents or approvals of any governmental or regulatory <br />authority necessary for the construction, operation, and maintera cc of the Facility (the "Permits'). QS shall keep FPL <br />reasonably informed as to the status of its permitting efforts and shall promptly inform FPL of any Permits it is unable to <br />obtain, that are delayed, limited, suspended, terminated, or otherwise constrained in away that could limit, reduce, <br />interfere with, or preclude QS's ability to perform its obligations under this Contract (including a statement of whether and <br />to what extent this circumstance may limit or preclude QS's ability to perform under this Contract.) <br />3.2.4 Demonstrate to FPL's reasonable satisfaction that QS has established Site Control, an agreement for the <br />ownership or lease ofthe Facility's site, for the Term ofthe Contract. <br />3.25 Complete all environmental impact studies and comply with applicable environmental laws necessary for the <br />construction, operation, and maintenance ofthe Facility. <br />3.2.6 At FPL's request, provide to FPL electrical specifications and design drawings pertaining to the Facility <br />for FPL's review prior to finalizing design ofthe Facility and before beginning construction work based on such <br />specifications and drawings, provided FPL's review ofsuch specifications and design shall not be construed as endorsing <br />the specification, and design thereof, or as any express or implied warranties including performance, safety, durability or <br />reliability ofthe Facility. QS shall provide to FPL reasonable advance notice of any changes in the Facility and provide <br />to FPL specifications and design drawings of any such changes. <br />3.2.7 Within fifteen (15) days after the close *fetch month from the first month following the Effective Date until the <br />Capacity Delivery Date, provide to FPL a monthly progress report (in a form reasonably satisfactory to FPL) and agree to <br />regularly scheduled meetings between representatives of QS and FPL to review such monthly reports and discuss QS's <br />construction progress. The Monthly Progress Report shall indicate whether QS is on target to meet the Capacity Delivery <br />Date. If, for any reason, FPL has reason to believe that QS may fail to achieve the Capacity Delivery Date, then, upon <br />FPL's request, QS shall submit to FPL, within ten (10) business days of such request, a remedial action plan ("Remedial <br />Action Plan') that sets forth a detailed description of QS's proposed course of action to promptly achieve the Capacity <br />Delivery Date. Delivery oft Remedial Action Plan does not relieve QS of its obligation to meet the Capacity Delivery <br />Date. <br />3.3 FPL shall have the right, but not the obligation, to: <br />3.3.1 Inspect during business hours upon reasonable notice, or obtain copies of all Permits held by QS. <br />3.32 Consistent with Section 3.2.6. notify QS in writing ofthe results of the review within thirty (30) days of FPL's <br />receipt ofall specifications for the Facility, including a description ofany flaws perceived by FPL in the design. <br />3.3.3 Inspect the Facility's construction site or on-site QS data and information pertaining to the Facility during <br />business hours upon reasonable notice. <br />(Continued on Sheet No. 9.033) <br />Issued by: S. E. Romig, Director, Rates and Tariffs <br />Effective: September 13, 2016 <br />'7 <br />l o <br />