Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Rough carpentry attachment shall meet the requirements herein and that of the <br /> current FM Loss Prevention Data Sheet 1-49,Perimeter Flashing. <br /> 4. Install bolts flush with the top surface of nailers where possible to avoid <br /> countersinking. Bolt bottom nailers then fasten upper nailers where possible. <br /> Countersink bolts,nuts and screws flush with wood surfaces only as detailed. <br /> 5. Install fasteners without splitting wood. Pre-drill where necessary. Split or <br /> damaged wood shall be removed, or repaired and/or re-secured secured to provide <br /> acceptable conditions. <br /> 6. For anchors, pre-drill concrete and masonry units to prevent damage or cracking <br /> of the masonry. Consult fastener manufacturer's published guides. Damaged <br /> masonry shall be repaired, and fasteners shall be removed and re-installed in an <br /> acceptable location. <br /> 7. Fastener spacing: Fasteners shall be staggered 1/3 the board width and installed <br /> within 6"of each end. <br /> a. Bolts, adhesive anchors, wedge and sleeve anchors, and machine bolts <br /> securing nailers shall be spaced 48 inches on center, staggered and an <br /> additional fastener within 6 inches of each end of nailer to prevent boards <br /> from twisting at board joints. Secure at 24"on center in corners(Zone 3) <br /> of the roof area. <br /> b. Screws and 1/4 inch diameter anchors securing wood to concrete or <br /> masonry units shall be spaced 12 inches on center maximum, staggered, <br /> with fasteners installed at each end of nailer lengths to prevent wood <br /> from twisting at board joints. <br /> c. Screws securing wood to wood shall be installed 12 inches apart, <br /> staggered,with two screws installed within 6 inches of each end of nailer <br /> lengths to prevent wood from twisting at board joints. <br /> d. Screws securing wood to steel decking shall be 12 inches apart. <br /> e. Self-drilling, and/or pre-drilled self-tapping screws securing wood to <br /> structural steel shall be spaced 12 inches apart, staggered,with one screw <br /> within 6 inches of each end of nailer lengths to prevent wood from <br /> twisting at board joints. <br /> f. Nails securing wood to wood shall be spaced 12 inches apart, staggered, <br /> with two nails installed within 6 inches of each end of nailer lengths to <br /> prevent wood from twisting at board joints. <br /> H. Select fasteners of size and length that will not be exposed from the building interior <br /> and/or from the ground, or remove protruding fasteners, paint or finish to eliminate <br /> exposure. <br /> I. Thickness of wood nailers shall be flush with adjacent insulation and other materials. <br /> Additional fasteners shall be installed to ensure nailers are flush. <br /> J. Unless otherwise detailed, plywood used as blocking or shim shall be installed below <br /> dimensional lumber such that the fastener head terminates at the dimensional lumber <br /> surface. <br /> K. Wood nailers at roof perimeters,expansion joints,roof area dividers, etc. shall not be less <br /> than 3 feet long. <br /> L. When multiple nailers are installed stacked two high or more, offset nailers no less than <br /> 12" such that joints at nailer end do not line-up vertically. <br /> M. Each end of nailers shall be fastened with additional fasteners to ensure .a smooth <br /> Sebastian Corners Roof.Replacement 06 10 00-8 Rough Carpentry <br />