My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 07 22 16 <br /> ROOF INSULATION <br /> PART1 GENERAL <br /> 1.01 SECTION INCLUDES <br /> A. Roof Sector A: Prepare existing steel deck, loose lay insulation system and provide <br /> crickets where indicated on contract documents. Then mechanically attach gypsum <br /> overlayment through insulation system into top flange of steel deck. <br /> B. Roof Sector B: Prepare existing steel deck, loose lay tapered insulation system and <br /> provide crickets where indicated on contract documents. Then mechanically attach <br /> gypsum overlayment through insulation system into top flange of steel deck. <br /> 1.02 RELATED DOCUMENTS <br /> A. Drawings and general provisions of the Contract, including General and Supplementary <br /> Conditions and Specification Sections,apply to this Section, including but not limited to: <br /> 1. Steel Roof Deck Repair/Securement Section 05 31 23 <br /> 2. Rough Carpentry Section 06 10 00 <br /> 3. Preparation for Reroofing Section 07 01 50 <br /> 4. Thermoplastic Single Ply Roofing Section 07 54 00 <br /> 1.03 REFERENCES <br /> A. Refer to the following references for specification compliance: <br /> 1. Florida Building Code(FBC) <br /> 2. National Roofing Contractors Association—NRCA <br /> 3. FM Global <br /> 4. Underwriters Laboratories,Inc.—UL <br /> 5. ASHRAE Standard 90.1 <br /> 1.04 DESCRIPTION <br /> A. R Value <br /> 1. The minimum continuous "R-value" for the above deck insulation system shall <br /> be 20 and in accordance with the current Energy Conservation Code and <br /> ASHRAE 90.1. <br /> 2. R value to be based on Long-Term Thermal Resistance (LTTR) for <br /> polyisocyanurate insulation and manufacturer's published data for all other <br /> insulation components,as tested in accordance with ASTM C177,C236,C518 or <br /> C976. <br /> 1.05 SUBMITTALS <br /> A. Refer to Section 01 33 00-Submittal Procedures for requirements. <br /> B. Manufacturer's Product Data Sheets for all materials specified certifying material <br /> complies with all specified requirements. <br /> Sebastian Corners Roof Replacement 07 22 16-1 Roof Insulation <br />