My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. Refer to the Contract Drawings for perimeter and corner layout. <br /> 3. Hot-air weld overlaps according to membrane manufacturer's requirements. Seam <br /> test cuts shall be taken at least 3 times per day. <br /> C. Field Area <br /> 1. Over the properly installed and prepared substrate surface, full-width rolls(120") <br /> are to be installed perpendicular to the steel deck flutes. Membrane fasteners and <br /> plates are installed along the edge of the membrane on the fastening line six(6") <br /> inches on center. Plates are held-back 1 inch from the outer edge of the membrane. <br /> The adjacent full-roll is positioned to overlap the fastened edge of the first full-roll <br /> by 5-1/2 inches in accordance with the overlap lines marked on the sheet's edge. <br /> The 5-1/2 inch overlap will allow the top membrane to extend 2-1/2 inches past <br /> the membrane fastener and plate for heat-welding. Fasteners shall clamp the <br /> membrane tightly to the substrate. <br /> 2. Hot-air weld overlaps according to membrane manufacturer's recommendations. <br /> Seam test cuts shall be taken at least 3 times per day. <br /> 3.03 MEMBRANE TERMINATION <br /> A. Terminate membrane at all walls as shown in the contract drawings. <br /> 1. Roof Deck: Membrane shall be mechanically terminated using approved fasteners <br /> and plates six(6)inches on center. <br /> 2. Wood Wall Substrate: Membrane shall be turned up wall one inch and <br /> mechanically terminated using approved screws eight(8) inches on center with a <br /> termination bar. <br /> 3. Concrete/Masonry Wall Substrate: Membrane shall be turned up wall one inch <br /> and mechanically terminated using approved anchors eight (8) inches on center <br /> with a termination bar. <br /> B. Membrane shall extend over roof edge a minimum of 2" below the perimeter wood <br /> blocking. <br /> 3.04 FLASHING INSTALLATION <br /> A. General <br /> 1. All flashings shall be installed concurrently with the roof membrane as the job <br /> progresses. <br /> 2. No temporary ryflashin s shall be allowed without the prior written approval of the <br /> Engineer and Manufacturer. Approval shall only be for specific locations on <br /> specific dates. If any water is allowed to enter under the newly completed roofing, <br /> the affected area shall be removed and replaced at the Contractor's expense. <br /> 3. Seams shall not be "taped" as temporary measure but shall be fully completed <br /> before the end of each day. <br /> 4. Flashing shall be adhered to compatible, dry, smooth, and solvent-resistant <br /> surfaces. <br /> 5. Where substrates are incompatible with adhesives and PVC materials, the <br /> Contractor shall remove the incompatible materials and replace it with a <br /> compatible substrate,or install compatible PVC flashing materials. <br /> 6. Use caution to ensure adhesive fumes are not drawn into the building. <br /> B. Adhesive for Flashing Membrane <br /> Sebastian Corners Roof Replacement 07 54 00-7 Thermoplastic Single Ply Roofing <br />
The URL can be used to link to this page
Your browser does not support the video tag.