Laserfiche WebLink
c. Counterflashing <br /> d. Coping <br /> e. Gutter <br /> f. Collector Head <br /> g. Scupper Face Plate <br /> h. Downspouts <br /> 2.02 GALVALUME <br /> A. Galvalume coated steel meeting or exceeding AZ50 per ASTM A792 <br /> 1. 22 gauge <br /> a. Continuous Cleat <br /> 2.03 STAINLESS STEEL <br /> A. 26 gauge,Type 304 as tested in accordance with ASTM A 167. <br /> 1. Multiple Pipe Enclosure Components <br /> a. Pipe Enclosure Flashing <br /> b. Closure Cap <br /> 2. Pitch Pan <br /> B. Compression Bar: 1/4"X 1.5"stainless steel flat bar. <br /> 2.04 LEAD <br /> A. Four pound soft lead: <br /> 1. Soil Pipe Flashing <br /> 2. Roof Drain Flashing—utilize 30"x 30"sheet <br /> 3. Lead Wedges <br /> 2.05 POLYMER CLAD METAL(PVC) <br /> A. Polymer Clad Metal—Heat-weldable, 24 gauge, AISI G90 galvanized steel sheet with a <br /> 20-mil unsupported thermoplastic membrane coating to match the flashing membrane <br /> composition laminated on one side. Polymer-Clad metal shall be manufactured by, and <br /> included in the warranty of,the single-ply membrane Manufacturer. Color shall be selected <br /> by Owner. <br /> 1. Flange/Sleeve <br /> 2. Metal Edge <br /> 3. Scupper Liner <br /> 2.06 FASTENERS <br /> A. Roofing Nails: 11 or 12 gauge stainless steel ring shank roofing nails with diamond point, <br /> minimum 3/8" diameter head and length as required to penetrate substrate a minimum of <br /> 1-1/4". <br /> B. Screws: <br /> Sebastian Corners Roof Replacement 07 62 00-3 Sheet Metal Flashing and Trim <br />