My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
manufactured by ThoRoc (ChemRex), Multi Purpose Non-Shrink Grout as manufactured <br /> by US Mix,or Sikagrout 212 as manufactured by Sika. <br /> K. Pourable Sealer:Two part pourable polyurethane sealant conforming to ASTM D 429,and <br /> designed to seal around penetrations. <br /> PART 3 EXECUTION <br /> 3.01 EXAMINATION <br /> A. Coordinate with other work for correct sequencing of items which make up the entire <br /> system. <br /> B. Ensure substrates are installed, secured and modified to accommodate sheet metal <br /> flashings. <br /> C. Deficiencies associated with the sheet metal substrates shall be reported to Engineer before <br /> beginning sheet metal work. All such deficiencies shall be corrected before installing sheet <br /> metal flashings. <br /> 3.02 INSTALLATION <br /> A. General: <br /> 1. All joints to be locked and sealed or soldered. <br /> 2. Provide for thermal movement (expansion and contraction) of all exposed sheet <br /> metal. <br /> 3. Where dissimilar metals contact, galvanic action shall be prevented by means of <br /> heavy coat of asphalt paint. <br /> 4. All metal flanges shall be installed on top of membrane and adhered as indicated <br /> in detail drawings. Metal flanges connected to the roof shall be installed per <br /> membrane manufacturer's specifications and the requirements herein. <br /> 5. Various sheet metal sections shall be uniform with corners, joints and angles <br /> mitered,sealed and secured. <br /> 6. Exposed edges shall be returned(hemmed);both for strength and appearance,and <br /> sheet metal shall be fitted closely and neatly. <br /> 7. Provide cleats or stiffeners and other reinforcements to make all sections rigid and <br /> substantial. <br /> 8. Sheet metal shall be fabricated,supported, cleated, fastened and joined to prevent <br /> warping,"oil canning",and buckling. <br /> 9. All sheet metal details shall provide for redundancy including but not limited to <br /> sheet metal underlayment and/or sealants. This secondary protection shall be <br /> installed, sealed and lapped to ensure a redundant layer of protection will shed <br /> moisture infiltration in the sheet metal fails. <br /> B. Sheet Metal Underlayment: <br /> 1. Fully adhere to substrates where indicated in Contract Drawings. <br /> 2. Lap adjoining sections a minimum of 3" and fully adhere. <br /> 3. Shall extend beyond wood blocking a minimum of 1" at roof edges and parapet <br /> walls. <br /> 4. At roof edges and parapet walls, sheet metal underlayment shall be installed <br /> concurrently with roof membrane and flashing installation. Temporary weather <br /> Sebastian Corners Roof Replacement 07 62 00-5 Sheet Metal Flashing and Trim <br />
The URL can be used to link to this page
Your browser does not support the video tag.