My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
protection utilizing other materials is not acceptable when sheet metal <br /> underlayment is specified. <br /> C. Fasteners: Shall be size and type required. <br /> 1. All fasteners to be rust resistant and compatible with materials to be joined. <br /> 2. All exposed fasteners shall be stainless steel screws with washers fastened through <br /> 5/16"predrilled oversized holes. <br /> 3. All exposed fasteners into concrete or masonry shall be metal based expansion <br /> anchor with stainless steel pin with washers fastened through 11/32" predrilled <br /> oversized holes. <br /> 4. All exposed fasteners shall have factory painted heads to match the sheet metal <br /> color. <br /> 5. Exposed horizontal surface fasteners are not acceptable. <br /> D. Soil Pipe <br /> 1. Provide Prefabricated Pipe Penetration Flashing as shown in detail drawing with a <br /> 4"minimum flange. <br /> 2. Set flange in a full bed of roofing cement over base ply and strip in as specified. <br /> 3. Provide separate flashing cap extending a minimum of 1"down inside pipe,and a <br /> minimum of 3" down outside the pipe. <br /> 4. Clean and solder all seams. <br /> E. Pipe Penetration <br /> 1. Fabricate flange/sleeve and umbrellas as shown in detail drawings. Refer to <br /> SMACNA Architectural Sheet Metal Manual Figure 8-9C. <br /> 2. Provide a 4"minimum flange attached and stripped in as indicated in the Contract <br /> Drawings. <br /> 3. Install watertight umbrella with stainless steel draw band and sealant properly <br /> tooled to ensure adhesion and slope to shed water. <br /> 4. Vertical leg of umbrella flashing shall extend a minimum of 2" below the sleeve <br /> top and be positioned as low as possible on the sleeve. <br /> 5. Clean and solder all seams. <br /> F. Slip Flashing for Curbs <br /> 1. Fabricate slip flashing at curbs as shown in detail drawings in 10'lengths. <br /> 2. Slip flashing shall extend a minimum of 2 inches below base flashing termination <br /> and shall fit tightly against curb. <br /> 3. Secure slip flashing 12"on center of a minimum of two fasteners per side of the <br /> curb. <br /> 4. Notch and lap ends of adjoining sections not less than 4"; apply sealant tape <br /> between sections. <br /> 5. Lap miters at corners a minimum of 1 inch and apply sealant between laps. Rivet <br /> at 2"on center. <br /> G. Equipment Support <br /> 1. Wrap top of equipment support with sheet metal underlayment to extend two <br /> inches below base flashing termination. <br /> 2. Fabricate equipment support cap at curbs as shown in detail drawings in one <br /> continuous piece of sheet metal and secure at eighteen inches on center. <br /> Sebastian Corners Roof Replacement 07 62 00-6 Sheet Metal Flashing and Trim <br />
The URL can be used to link to this page
Your browser does not support the video tag.