My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H. Parapet Wall <br /> 1. Fabricate coping in 10' lengths. Width of coping shall be fabricated to be a <br /> maximum of 1/2" wider than the width of the wall; Contractor is responsible to <br /> field verify parapet wall width prior to sheet metal fabrication. Refer to SMACNA <br /> Architectural Sheet Metal Manual Figure 3-4A. <br /> 2. Install tapered edge strip mechanically attached or set in foam adhesive to top of <br /> wood blocking. <br /> 3. Install flashing membrane up and over parapet extending a minimum of 1" below <br /> wood blocking. <br /> g <br /> 4. Install continuous cleat fastened to substrate 6" on center in vertical leg. Locate <br /> fasteners no greater than 2"from the bottom hem. <br /> 5. Lock outside face of coping onto continuous cleat and secure inside face as <br /> follows: <br /> a. For coping widths up to and including 12 inches, secure with screws <br /> through waterproof washers and oversized holes at 18 inches on center. <br /> b. For coping widths greater than 12 inches, secure inside face with <br /> continuous cleats. Secure cleat through vertical face of cleat to blocking <br /> with fasteners at 6 inches on center. Locate fasteners no greater than 2 <br /> inches from the bottom hem. <br /> 6. Provide drive seam at adjoining coping sections. Turn cover ends back a minimum <br /> of 1" onto itself. Allow Vi" space between coping sections for expansion and <br /> contraction and install sealant. Refer to SMACNA Architectural Sheet Metal <br /> Manual Figure 3-2,type 4. <br /> 7. Provide one-piece coping section at four way and tee intersections. <br /> 8. Turn coping ends up a minimum of 2" at elevation walls and cover termination <br /> with surface mounted counterflashing. <br /> Through-Wall Primary/Overflow Scupper <br /> 1. Fabricate thru-wall scupper flange, liner, and faceplate as shown in detail <br /> drawings. Scuppers dimensions shall be as indicated in the Contract Drawings. <br /> 2. Hot-air weld stripping membrane at seams of the flange and liner. <br /> 3. Install flashing membrane through scupper opening prior to installing new scupper <br /> to seal wall cavity. <br /> 4. Provide flange which extends a minimum of 4"on top and sides of scupper, and <br /> extends a minimum of 4"out onto the horizontal membrane. Mechanically fasten <br /> the horizontal flange into structural deck 8" on center or a minimum of two <br /> fasteners per scupper with approved fasteners. <br /> 5. Strip-in flange as specified in Contract Drawings. <br /> 6. Provide faceplate which extends 1.5"around the entire scupper and secure to wall <br /> substrate with four fasteners. Set faceplate in a bead of sealant. <br /> 7. Scupper Liner shall extend 1" beyond the exterior wall face and lock onto <br /> faceplate. <br /> 8. Collector Heads: <br /> a. Fabricate collector heads as shown in detail drawings. Refer to SMACNA <br /> Architectural Sheet Metal Manual Figure 1-25F. <br /> b. All joints to be sealed and pop riveted. Install beads of sealant inside <br /> conductor head at all seams and rivets. <br /> c. Back edge of conductor head shall be locked to through-wall scupper. <br /> Refer to SMACNA Architectural Sheet Metal Manual Figure 1-26A. <br /> Sebastian Corners Roof Replacement 07 62 00-7 Sheet Metal Flashing and Trim <br />