My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 01 50 00 <br /> TEMPORARY FACILITIES AND CONTROLS <br /> PART 1 GENERAL <br /> 1.01 SECTION INCLUDES <br /> A. This Section includes requirements for temporary facilities and controls, including <br /> temporary utilities, support facilities,and security and protection facilities. <br /> PART 2 PRODUCTS <br /> 2.01 MATERIALS <br /> A. General: Provide new materials. Undamaged, previously used materials in serviceable <br /> condition may be used if approved by Engineer. Provide materials suitable for use <br /> intended. <br /> B. Portable Chain-Link Fencing: Minimum 2-inch 9-gage,galvanized steel,chain-link fabric <br /> fencing; minimum 6 feet high with galvanized steel pipe posts; minimum 2-3/8-inch-OD <br /> line posts and 2-7/8-inch- OD corner and pull posts,with 1-5/8-inch- OD top and bottom <br /> rails. Provide non-permanent bases for support. <br /> C. Tarpaulins: Fire-resistive labeled with flame-spread rating of 15 or less. <br /> D. Water: Potable. <br /> E. Self-Contained Toilet Units: Single-occupant units of chemical, aerated recirculation, or <br /> combustion type; vented; fully enclosed with a glass-fiber-reinforced polyester shell or <br /> similar nonabsorbent material. <br /> F. Electrical Outlets: Properly configured, NEMA-polarized outlets to prevent insertion of <br /> 110- to 120-V plugs into higher-voltage outlets; equipped with ground-fault circuit <br /> interrupters,reset button,and pilot light. <br /> G. Fire Extinguishers: Hand carried, portable, UL rated. Provide class and extinguishing <br /> agent as indicated or a combination of extinguishers of NFPA-recommended classes for <br /> exposures. <br /> 1. Comply with NFPA 10 and NFPA 241 for classification,extinguishing agent,and <br /> size required by location and class of fire exposure and the requirements of the <br /> local Governing agency. <br /> H. Lamps and Light Fixtures:Provide GFCI protected general service incandescent lamps of <br /> wattage required for adequate illumination. Provide guard cages or tempered glass <br /> enclosures where exposed to breakage. Provide exterior fixtures where exposed to <br /> moisture. <br /> I. Scaffolds: Scaffolds should be built in their entirety and not left unfinished or in an unsafe <br /> condition. All scaffolds must be tagged to indicate the latest inspection. Scaffolds should <br /> be tied into the structure as close to a 3:1 ratio as possible and repeated tie-ins shall follow <br /> OSHA guidelines. All scaffolds shall have safe access with stairs being the first choice <br /> over a ladder. Scaffolds should include netting on upper levels if there is any possibility <br /> for materials to fall over the toe boards,per OSHA guidelines. <br /> Sebastian Corners Roof Replacement 01 50 00-1 Temporary Facilities and Controls <br />
The URL can be used to link to this page
Your browser does not support the video tag.