Laserfiche WebLink
SECTION 01 50 00 <br /> TEMPORARY FACILITIES AND CONTROLS <br /> PART 1 GENERAL <br /> 1.01 SECTION INCLUDES <br /> A. This Section includes requirements for temporary facilities and controls, including <br /> temporary utilities, support facilities,and security and protection facilities. <br /> PART 2 PRODUCTS <br /> 2.01 MATERIALS <br /> A. General: Provide new materials. Undamaged, previously used materials in serviceable <br /> condition may be used if approved by Engineer. Provide materials suitable for use <br /> intended. <br /> B. Portable Chain-Link Fencing: Minimum 2-inch 9-gage,galvanized steel,chain-link fabric <br /> fencing; minimum 6 feet high with galvanized steel pipe posts; minimum 2-3/8-inch-OD <br /> line posts and 2-7/8-inch- OD corner and pull posts,with 1-5/8-inch- OD top and bottom <br /> rails. Provide non-permanent bases for support. <br /> C. Tarpaulins: Fire-resistive labeled with flame-spread rating of 15 or less. <br /> D. Water: Potable. <br /> E. Self-Contained Toilet Units: Single-occupant units of chemical, aerated recirculation, or <br /> combustion type; vented; fully enclosed with a glass-fiber-reinforced polyester shell or <br /> similar nonabsorbent material. <br /> F. Electrical Outlets: Properly configured, NEMA-polarized outlets to prevent insertion of <br /> 110- to 120-V plugs into higher-voltage outlets; equipped with ground-fault circuit <br /> interrupters,reset button,and pilot light. <br /> G. Fire Extinguishers: Hand carried, portable, UL rated. Provide class and extinguishing <br /> agent as indicated or a combination of extinguishers of NFPA-recommended classes for <br /> exposures. <br /> 1. Comply with NFPA 10 and NFPA 241 for classification,extinguishing agent,and <br /> size required by location and class of fire exposure and the requirements of the <br /> local Governing agency. <br /> H. Lamps and Light Fixtures:Provide GFCI protected general service incandescent lamps of <br /> wattage required for adequate illumination. Provide guard cages or tempered glass <br /> enclosures where exposed to breakage. Provide exterior fixtures where exposed to <br /> moisture. <br /> I. Scaffolds: Scaffolds should be built in their entirety and not left unfinished or in an unsafe <br /> condition. All scaffolds must be tagged to indicate the latest inspection. Scaffolds should <br /> be tied into the structure as close to a 3:1 ratio as possible and repeated tie-ins shall follow <br /> OSHA guidelines. All scaffolds shall have safe access with stairs being the first choice <br /> over a ladder. Scaffolds should include netting on upper levels if there is any possibility <br /> for materials to fall over the toe boards,per OSHA guidelines. <br /> Sebastian Corners Roof Replacement 01 50 00-1 Temporary Facilities and Controls <br />