Laserfiche WebLink
A TRUE COPY <br />CERTIFICATION ON LAST PAGE <br />J.R. SMITH, CLERK <br />which is more than fifty feet (50') in height if such pole was installed to meet FPL's own <br />service requirements. <br />(d) Permission to Attach to FPL Transmission Poles. <br />Licensee may attach its Wireline in New Attachments to FPL transmission poles <br />with distribution underbuilt as provided herein. Wireline in New Attachments to <br />transmission poles with distribution underbuilt shall be permitted only in the <br />Communications Space. In applying for New Attachments, Licensee shall follow the <br />procedures in the FPL Permit Application Process Manual for Wireline Attachments to <br />Transmission Poles. Existing Attachments in the Communications Space shall be <br />rearranged at Licensee's expense should they be found to be in violation of any of the <br />standards defined in Section 3.5. <br />(e) Inspection. <br />Prior to applying for permission to attach any New Attachments to any FPL <br />pole(s), Licensee shall inspect the pole(s) to which it wishes to attach the New <br />Attachments and shall prepare a windloading study and calculations according to FPL <br />requirements. If any pole or poles of FPL must be reworked or are inadequate to support <br />the additional facilities in accordance with the specifications_ in Article III below, Licensee <br />will request Make -Ready Work by indicating the necessary changes on Exhibit A. <br />2.4 Florida Power & Light Company Permit. After inspection and prior to <br />attaching any New Attachment to any FPL pole, Licensee shall apply for and receive a written <br />permit in the form of Exhibit A. Licensee shall attach its windloading calculations and pole and <br />mid -span clearance measurements to its permit application. FPL may deny a permit for New <br />Attachments if, in the sole judgment of FPL, such attachment will interfere with FPL's system <br />integrity or service requirements, including economic, safety, reliability and engineering <br />requirements. No New Attachments shall be permitted except as provided in this Article II above. <br />ARTICLE III <br />ATTACHMENT AND MAINTENANCE <br />3.1 Attachments of OPGW to Transmission Poles. <br />(a) OPGW. No New Attachments will be allowed in the Supply Space unless <br />such New Attachments will be attached to Existing Attachments in the Supply Space. <br />Licensee shall not perform any work on OPGW which is attached to FPL transmission <br />poles. All such work, including the installation of New Attachments, maintenance, <br />Rearrangement or the removal of any portion of System, in connection with the installation <br />of such New Attachments, shall be performed by FPL at Licensee's expense, as provided <br />in Section 3.8 and Article IV below. <br />(b) NESC and FPL Requirements. All FPL Attachment -related work on. the <br />System shall be performed in accordance with the requirements and specifications of the <br />NESC, latest edition, or any applicable amendments, revisions or subsequent editions of <br />the NESC, as well as any additional requirements of FPL. <br />3.2 Attachments to Distribution Poles and Transmission Poles with Distribution <br />Underbuilt. Licensee, at its own expense, shall make and maintain its Attachments to distribution <br />Confidential 4 Linear Facilities Attachment Agreement 116402702.1 <br />