My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-085B
CBCC
>
Official Documents
>
2010's
>
2019
>
2019-085B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2019 1:19:57 PM
Creation date
6/10/2019 2:21:31 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
06/04/2019
Control Number
2019-085B
Agenda Item Number
8.K.
Entity Name
REI Engineers
Subject
Roof Replacements
Area
Central Wastewater Treatment Plan
Project Number
IRC-1829
Alternate Name
Work Order No. 7
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEERS <br />May 23,'2019 <br />Indian River County <br />1801 27th Street <br />Vero Beach,FL 32960 <br />Attention: Andrew Sobczak <br />Infrastructure Project Manager <br />Reference: Proposal for Engineering Services <br />Contract Documents and Construction Administration <br />IRC Central Wastewater Treatment Plant <br />REI Proposal No. P19TPA-014 <br />Dear Mr. Sobczak: <br />In response to ourrecent correspondence, we are pleased to submit this proposalfor your consideration. The <br />roof areas outlined in this proposal include the eight Areas (totaling approximately 12,785 square feet) of the <br />facility located at 3550 49th St, Vero Beach, FL 32967. The following is an outline of the proposed services for <br />Contract Documents and Construction Administration: <br />I. CONTRACT DOCUMENTS (CD) <br />A. Conduct site visit(s) to develop detailed Contract Documents for the subject facility. <br />B Extract roof samples to identify roof system composition and condition. Cored locations to be <br />repaired with compatible materials: <br />C. Perform the following engineering design calculations for 'aII roof areas which will be sealed by a <br />Licensed Engineer: <br />1 Determine design wind loads in accordance with ASCE 7 as required by the current edition <br />of the State Building Code. <br />2. Primary and secondary (overflow) drainage for compliance with the current edition of the <br />State Plumbing Code. <br />3 Existing and proposed roof system R -Value for compliance with the current edition of the <br />State Energy Conservation Code. <br />4. Estimate existing and proposed roof system dead load unit weights to determine load <br />change and the need for a structural analysis. If a structural analysisis required, REI will <br />coordinate applicable work with a licensed Structural Engineer. The cost for the structural <br />analysis (if necessary) is not included in this proposal. <br />PAGE 1 OF 4 <br />Engineering solutions for tomorrow' <br />10150 Highland Manor Drive, Suite 200 reiengineers.com <br />813.944.2137 <br />Tampa. FL 33610 <br />
The URL can be used to link to this page
Your browser does not support the video tag.