My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-190A
CBCC
>
Official Documents
>
2010's
>
2019
>
2019-190A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2019 11:18:33 AM
Creation date
12/11/2019 11:14:32 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/12/2019
Control Number
2019-190A
Agenda Item Number
8.D.
Entity Name
Tech Systems
Subject
North County Regional Park Aquatic Center Rood Replacement Contract
Area
North County Pool
Project Number
IRC-1826
Bid Number
2019074
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOFING REPLACEMENT PROJECT <br />NORTH COUNTY REGIONAL PARK AQUATIC CENTER <br />JUNE 7, 2019 <br />B. Sample warranty. <br />1.5 CLOSEOUT SUBMITTALS <br />A. Maintenance data. <br />B. Special warranty. <br />1.6 QUALITY ASSURANCE <br />PAGE 2 <br />SECTION 076200 <br />SHEET METAL AND FLASHINGS <br />A. Fabricator Qualifications: Employs skilled workers who custom fabricate sheet metal <br />flashing and trim similar to that required for this Project and whose products have a <br />record of successful in-service performance. <br />1.7 WARRANTY <br />A. Special Warranty on Finishes: Manufacturer agrees to repair finish or replace sheet <br />metal flashing and trim that shows evidence of deterioration of factory -applied finishes <br />within specified warranty period. <br />a. Cracking, checking, peeling, or failure of paint to adhere to bare metal. <br />2. Finish Warranty Period: 20 years from date of Substantial Completion. <br />PART 2 - PRODUCTS <br />2.1 PERFORMANCE REQUIREMENTS <br />A. General: Sheet metal flashing and trim assemblies, including cleats, anchors, and <br />fasteners, shall withstand wind loads, structural movement, thermally induced <br />movement, and exposure to weather without failure due to defective manufacture, <br />fabrication, installation, or other defects in construction. Completed sheet metal <br />flashing and trim shall not rattle, leak, or loosen, and shall remain watertight. <br />B. Sheet Metal Standard for Flashing and Trim: Comply with NRCA's "The NRCA Roofing <br />Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and <br />Reroofing" and SMACNA's "Architectural Sheet Metal Manual" requirements for <br />dimensions and profiles shown unless more stringent requirements are indicated. <br />C. SPRI Wind Design Standard: Manufacture and install copings and roof edge flashings <br />tested in accordance with ANSI/SPRI/FM 4435/ES-1 and capable of resisting the <br />following design pressure: <br />Design Pressure: As indicated on Drawings. <br />D. Thermal Movements: Allow for thermal movements from ambient and surface <br />temperature changes to prevent buckling, opening of joints, overstressing of <br />
The URL can be used to link to this page
Your browser does not support the video tag.