INDIAN RIVER COUNTY — NORTH COUNTY REGIONAL PARK <br />AQUATIC FACILITY ROOFING REPLACEMENT <br />JUNE 7, 2019 <br />DIVISION 7 — THERMAL AND MOISTURE PROTECTION <br />SECTION 074210 - METAL WALL PANELS <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />PAGE 1 <br />SECTION 074210 <br />METAL WALL PANELS <br />A. Drawings and general provisions of the Contract, including General and Supplementary <br />Conditions and Division 01 Specification Sections, apply to this Section. <br />1.2 SUMMARY <br />A. Section Includes: <br />1. Concealed -fastener, lap -seam metal wall panels. <br />B. Related Sections: <br />1. Section 076200 "Sheet Metal Flashing and Trim" for flashing and other sheet metal work <br />that is not part of metal wall panel assemblies. <br />1.3 DEFINITION <br />A. Metal Wall Panel Assembly: Metal wall panels, attachment system components, miscellaneous <br />metal framing, thermal insulation, and accessories necessary for a complete weathertight wall <br />system. <br />1.4 PERFORMANCE REQUIREMENTS <br />A. General Performance: Metal wall panel assemblies shall comply with performance requirements <br />without failure due to defective manufacture, fabrication, installation, or other defects in <br />construction. <br />B. Delegated Design: Design metal wall panel assembly, including comprehensive engineering <br />analysis by a qualified professional engineer, using performance requirements and design criteria <br />indicated. <br />C. Water Penetration under Static Pressure: No water penetration when tested according to <br />ASTM E 331 at the following test -pressure difference: <br />1. Test -Pressure Difference: 6.24 Ibf/sq. ft. (300 Pa). <br />D. Structural Performance: Provide metal wall panel assemblies capable of withstanding the effects <br />the following loads and stresses within limits and under conditions indicated, based on testing <br />according to ASTM E 1592: <br />1. Wind Loads: Determine loads based on ASCE 7-10: <br />