My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-190A
CBCC
>
Official Documents
>
2010's
>
2019
>
2019-190A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2019 11:18:33 AM
Creation date
12/11/2019 11:14:32 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/12/2019
Control Number
2019-190A
Agenda Item Number
8.D.
Entity Name
Tech Systems
Subject
North County Regional Park Aquatic Center Rood Replacement Contract
Area
North County Pool
Project Number
IRC-1826
Bid Number
2019074
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY — NORTH COUNTY REGIONAL PARK PAGE 2 <br />AQUATIC FACILITY ROOFING REPLACEMENT SECTION 074210 <br />JUNE 7, 2019 METAL WALL PANELS <br />2. Deflection Limits: Metal wall panel assemblies shall withstand wind loads with horizontal <br />deflections no greater than 1/180 of the span. <br />E. Thermal Movements: Allow for thermal movements from ambient and surface temperature <br />changes by preventing buckling, opening of joints, overstressing of components, failure of joint <br />sealants, failure of connections, and other detrimental effects. Base calculations on surface <br />temperatures of materials due to both solar heat gain and nighttime -sky heat loss. <br />1. Temperature Change (Range): 180 degrees Fahrenheit. <br />1.5 ACTION SUBMITTALS <br />A. Product Data: For each type of product indicated. Include construction details, material <br />descriptions, dimensions of individual components and profiles, and finishes for each type of wall <br />panel and accessory. <br />B. Shop Drawings: Show fabrication and installation layouts of metal wall panels; details of edge <br />conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings, <br />closures, and accessories; and special details. Distinguish between factory-, shop- and field - <br />assembled work. <br />Accessories: Include details of the following items, at a scale of not less than 1-1/2 inches <br />per 12 inches (1:10): <br />a. Flashing and trim. <br />b. Anchorage systems. <br />C. Samples for Verification: For each type of exposed finish required, prepared on Samples of size <br />indicated below. <br />1. Metal Soffit Panels: 12 inches (305 mm) long by actual panel width. Include fasteners, <br />closures, and other metal wall panel accessories. <br />2. Trim and Closures: 12 inches (305 mm) long. Include fasteners and other exposed <br />accessories. <br />3. Accessories: 12 -inch- (305 -mm-) long Samples for each type of accessory. <br />D. Delegated -Design Submittal: For metal wall panel assembly indicated to comply with performance <br />requirements and design criteria, including analysis data signed and sealed by the qualified <br />professional engineer responsible for their preparation. <br />1.6 INFORMATIONAL SUBMITTALS <br />A. Coordination Drawings: Exterior elevations drawn to scale and coordinating penetrations and <br />wall -mounted items. Show the following: <br />1. Wall panels and attachments. <br />2. Wall -mounted items including doors, windows, louvers, and lighting fixtures. <br />3. Penetrations of wall by pipes and utilities. <br />B. Qualification Data: For Installer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.