Laserfiche WebLink
INDIAN RIVER COUNTY — NORTH COUNTY REGIONAL PARK PAGE 4 <br />AQUATIC FACILITY ROOFING REPLACEMENT SECTION 075216 <br />JUNE 7, 2019 MODIFIED BITUMINOUS MEMBRANE ROOFING <br />N. Complete list of material physical and mechanical properties for each sheet including: <br />weights and thicknesses; low temperature flexibility; maximum load; elongation @ 5% <br />maximum load; breaking load; dimensional stability; high temperature stability; and <br />compound stability. <br />O. Sample copy of the specified guarantee. <br />1.9 CLOSE-OUT SUBMITTALS <br />A. Certificate Of Analysis from the testing laboratory of the primary waterproofing materials <br />manufacturer confirming the physical and mechanical properties of the roofing membrane <br />components. Testing shall be in accordance with the parameters published in ASTM D <br />5147 and ASTM D 7051 and indicate Quality Assurance/Quality Control Data as required <br />to meet the specified properties. A separate Certificate Of Analysis for each production <br />run of material shall indicate the following information: <br />1. Material type <br />2. Lot number <br />3. Production date <br />4. Dimensions and Mass (indicate the lowest values recorded during the production run) <br />5. Roll length <br />6. Roll width <br />7. Selvage width <br />8. Total thickness <br />9. Thickness at Selvedge (coating thickness) <br />10. Weight <br />11. Physical and Mechanical Properties <br />12. Low temperature flexibility <br />13. Peak Load <br />14. Ultimate Elongation <br />15. Dimensional stability <br />16. Compound Stability <br />