My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-116D-2
CBCC
>
Official Documents
>
2020's
>
2020
>
2020-116D-2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2020 3:31:29 PM
Creation date
7/28/2020 3:30:18 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Manual
Approved Date
06/23/2020
Control Number
2020-116D-1
Agenda Item Number
8.N.
Entity Name
Atlantic Roofing
Main Library
Subject
Replacement Roof
Project Number
IRC-1838
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IRC-1838 Indian River County <br />Main Library <br />Roof Replacement 05 31 23-5 Steel Roof Deck Repair <br />fasteners 8” on center maximum or a minimum of 2 screws per side. <br />E. Corrosion Degree 5: <br />1. Examine underside of steel deck for any conduit located directly below the deck <br />surface, anything suspended or fastened to the deck surface, etc. If necessary, <br />detach all objects from the bottom side of the deck to be removed. <br />2. Any deck meeting Corrosion Degree 5 shall be removed in its entirety. <br />3. Provide roof deck where existing is removed. <br />4. Overlap all deck end laps no less than 6" and as required to secure through both <br />panels and into the structural steel. Lap ends only over structural framing. Deck <br />fasteners shall penetrate deck panels no less than 2" from the edge of the panel. <br />5. Overlap all deck side laps to nest flush into neighboring deck panel. Install a <br />minimum of two deck side lap fasteners. <br />6. Workers shall apply their weight over the area being fastened to prevent deck <br />deflection and ensure complete contact between fasteners, deck and/or structural <br />steel. <br />7. Follow deck Manufacturer’s instructions and the latest edition of the Steel Deck <br />Institute (SDI) Specifications and Commentary. <br />3.4 STEEL DECK SECUREMENT <br />A. Fasten all steel deck panels to steel framing and steel deck side laps as indicated in the <br />contract drawings. <br />1. Field of Roof: Fasten deck to joists 12" on centers, one fastener in every other <br />deck rib. <br />2. Perimeter of Roof: Fasten deck to joists 6" on centers, one fastener in every deck <br />rib. <br />3. Deck Side-Lap Fastening: <br />a. Install two (2) deck panel side-lap fasteners between joists. Equally space <br />the fasteners no greater than 30” apart. <br />4. Fastener position/location: <br />a. Deck fasteners shall be driven in the center of the bottom of the deck rib. <br />The fasteners shall be driven within +/- 1/4" of the center of the structural <br />steel bearing surface. The fasteners shall be driven along the center of the <br />structural steel member, not near the edge of the structural steel. <br />b. Deck side lap fasteners shall be driven into the deck rib such that both <br />panels are penetrated. The side lap fastener shall be located along the <br />center of the bottom of the rib. <br />5. Workers shall apply their weight over the area being fastened to prevent deck <br />deflection and ensure complete contact between fasteners, deck and/or structural <br />steel. <br />3.5 INSTALLATION <br />A. Contractor shall follow deck Manufacturer’s instructions and the latest edition of the Steel <br />Deck Institute (SDI) Specifications and Commentary. <br />B. Deck panels shall be installed straight and true and shall be aligned with adjacent panels <br />end and side laps without bending or binding the decking. <br />C. Deck panel ribs shall contact bar joist top chord angles and other steel framing.
The URL can be used to link to this page
Your browser does not support the video tag.