Laserfiche WebLink
ORDER NO. PSC -2020 -0212 -PAA -EQ <br />DOCKET NO. 20200114 -EQ <br />PAGE 9 <br />FI.ORWWA POWER & LIGHT COMPANY <br />Attachment A <br />First Revised Sheet No. 9.032.1 <br />Camels Original SheetNo.9.032.1 <br />(Continued from Sheet No. 9.032) <br />3.2 QS, at no cost to FPI:, shall be responsible to: <br />3.2. t Design, construct, and maintain the Facility in accordance with this Contract, applicable law, regulatory; and <br />govenurtenial approvals, any requirements of warranty agreements or similar agreements, prudent industry practice, <br />insurance policies, and the interconnection Agreement or Wheeling Agreement. <br />3.2.2 Perform all snuties, pay all fees, obtain all necessary approvals and execute all necessary agreements (including <br />the Interconnection Agreement or the Wheeling Agreenaint(s)) in order to schedule and deliver the firm capacity and <br />energy to FPL. <br />3.2.3 Obtain and rnaintainall.pernits, certifications, licenses, consents or approvals of any governmental or regulatory <br />authority necessary for the construction, operation, and maintenance of the Facility (the "Permits"). QS shall keep FPL <br />reasonably informed as to the status of its permitting efforts and slant promptyinfonn FPL of any Permits it is unable to <br />obtain, that are delayed, limited, suspended; terminated, or otherwise constrained in a way that could limit, reduce, <br />interfere with, or preclude QS's ability to perform its obligations ander this Contract (including a staterrnt of wl>rthcr and <br />to what extent this circumstance may limit or preclude QS's ability to perform under this Contract.) <br />3.2.4 Demonstrate to FPL's reasonable satisfaction that QS has established Site Control, an agreement for the <br />ownership or lease of the Facility's site, for the Tenn of the Contract. <br />3.2.5 Complete -all environmental impact studies and comply with applicable enviremnental laws necessary for the <br />construction, operation, and maintenance of the Facility. <br />3.2.6 At FPL's request, provide to FPL electrical specifications and design drawings -pertaining -to the Facility <br />feu FPL's review prior to finaliring design of the Facility and before'beginning construction work based of such <br />specifications and drawings, provided FPL's review of such -specifications and design shall not be construed as endorsing <br />the specification, and design thereof, or as any express or implicit warranties including performance, safety, durability or <br />reliability of the facility. QS shall .provide to FPL reasonable advance notice of any changes in the Facility and provide <br />to FPL specifications and design drawings of any such changes. <br />3.2.7 Within fifteen (15) days rifler the close of each month from the first month following the Effective Date until the <br />Capacity Delivery Date, provide to FPL a monthtyprogress report (in a form reasonably satisfactory to FPL) and agree to <br />regularly scheduled meetings between representativcs of QS and FP! o review §tach monthly reports and discuss QS's <br />eonstruetion progress. The Monthly Progress Report shall indicate whether QS is on target to meet the Capacity Delivery <br />Date. if,•for any reason, FPL has reason to believe that QS tray fail to achieve the Capacity Delivery pate, then, upon <br />FPL`s request, QS shall submit to FPL, within ten (10) business days of such request, a remedial action plan ("Remedial <br />Action Plan) that sets forth a detailed description of QS's proposed course of action to promptly achieve the Capacity <br />Delivery Date. Delivery of a Remedial Action Plan does not relieve QS of its obligation to meat the Capacity pd ivery <br />Date. <br />3.3 FPL shall have the right, but not the obligation, to: <br />3.3.1 Inspect (huing business hours upon reasonable notice, or obtain copies of all Permits -held by QS. <br />3.3.2 Consistent with Section 3.2.6. notify QS in writing of the results ofthe review within thirty (30) days of FPL's <br />receipt of all specifications for the Facility, including a description of any flaws perceived by FPL in the design. <br />3.3.3 inspect the Faeitity's constriction site or on-site QS data and information pertaining to the Facility during <br />business hours upon reasonable notice. <br />(Continued on Sheet No. 9.033) <br />Issued by: S. E. Romig, Director, Rates and Tariffs <br />Effective: September 13, 2016 <br />